![SICK A3M60 Advanced Operating Instructions Manual Download Page 19](http://html1.mh-extra.com/html/sick/a3m60-advanced/a3m60-advanced_operating-instructions-manual_1264516019.webp)
Commissioning
Operating Instructions
Chapter
4
19
8014012/1EF3/2021-12-08
Subject to change without notice
© SICK AG
•
Germany
•
All rights reserved
A3M60 Basic
Fig. 6: A3M60 Basic in
Additional Field Devices
Fig. 7: Communication
module on the slot for the
encoder
4.4.2
Loading encoders into the hardware configuration window
►
In
Additional Field Devices
open the folder
Encoders
.
►
Drag the icon for the AxM Encoder X.XX to the PROFIBUS DP master system using drag
and drop.
A window opens where you can enter the address of the A3M60 Basic on the
PROFIBUS.
4.4.3
Loading communication module into the slot
Two communication modules are allocated to the AxM Encoder Basic X.XX (see section 3.4
on page 11).
►
Drag the communication module Tel.IO<04 or Tel.IO<08 to the slot for the encoder.