Protection class
Circuit protection
U
V
connections reverse polarity protected
Output Q short-circuit protected
Output Q overload protected
1)
without load
Mechanical data
Table 24: Mechanical data
Connection type
M8, M12
Cable diameter
Ø 3.4 mm
Cable cross-section
AWG26, 0.14 mm²
Housing material
Aluminum and plastic PMMA
Overvoltage protection
1 A
Weight
30 g + 530 g * housing length
Communication interface
Table 25: Communication interface
IO-Link
V1.1
Data transmission rate
230.4 mm/s (COM3)
Cycle time
≤
2.3 ms
Process data length
32 Bytes
Process data structure
Each byte configurable
Factory setting
depending on type code
Maximum length of cable
20 m
Ambient environment
Table 26: Ambient environment
Enclosure rating
IP65, IP67
Electromagnetic compatibility
EN 61000-6-2
EMC radiated emission
EN 61000-6-4
Ambient temperature, operation
-25 °C ... +55 °C
Ambient temperature, storage
-25 °C ... +70 °C
Ambient light immunity
SLGxxx-xxxxAxxxxxx / SLGxxx-xxxxBxxxxxx:
30,000 lx direct sunlight
SLGxxx-xxxxCxxxxxx:
100,000 lx direct sunlight
Vibration resistance
Sine wave: 10-150 Hz, 0.35 mm
IEC 60068-2-6
Shock resistance
Single shocks: 15 g, 16 ms
Continuous shocks (500 per axis): 10 g,16 ms
DIN EN 60068-2-27
Smart Task
Table 27:
Smart Task
Smart Task
designation
Basic logic
Logic function
Direct, AND, OR
TECHNICAL DATA
11
8026014/2021-06-10 | SICK
O P E R A T I N G I N S T R U C T I O N S | SLG-2
53
Subject to change without notice