7.7
Smart Task
Figure 26: SOPAS - Smart Tasks tab
Using the
Smart Task
tab, the states of the individual zones (Q
int
1 – Q
int
4) can be
processed further and thus simple evaluations / size comparisons can be carried out.
These Q
int
states as well as an external input signal are possible input variables which
are available for selection in the
Input selector
.
Via the settings for
Logic 1/2
, the input signal of
Input selector 1
can be logically linked
with the input signal of
Input selector 2
.
OR
and
AND
logic gates are available for this
purpose.
Input selector 1
A00
Q
L
1
Logic 1
Timer 1
Inverter 1
Input selector 2
Q
L
2
Logic 2
Timer 2
Inverter 2
Figure 27: Logical principle of operation of the Smart Task function
Various delay modes can be selected via
Timer 1/2 mode
. The associated delay time is
set via
Time 1/2 setup
. See the graph below for details on how the various modes work.