background image

Operating Manual

Operating Manual

www.generlink.com

MA23-N (unit without whole house surge suppression)
MA23-S (unit with whole house surge suppression)
MA24-N (unit without whole house surge suppression)
MA24-S (unit with whole house surge suppression)

Operating Manual

Global Power Products, Inc.

225 Arnold Road 

Lawrenceville, GA 30044

1-800-886-3837 

[email protected]

www.generlink.com

OPER-MA23/24-N/S

2.20.20

Please refer

to page 22

for GenerLink™ 

testing,

while utility power

is present. 

Summary of Contents for MA23-N

Page 1: ...ion MA24 N unit without whole house surge suppression MA24 S unit with whole house surge suppression Operating Manual Global Power Products Inc 225 Arnold Road Lawrenceville GA 30044 1 800 886 3837 info globalpowerproducts com www generlink com OPER MA23 24 N S 2 20 20 Please refer to page 22 for GenerLink testing while utility power is present ...

Page 2: ...ch units Warranty on the repaired unit or any component thereof is limited to the balance of the original warranty period Surge Protection Manufacturers Limited Warranty Fifteen Year Product Coverage Global Power Products Inc will repair or replace any Surge Protection Device that is defective in material or workmanship or is damaged by an electrical surge including those caused by lightning for a...

Page 3: ...type le plus commun de Protection contre les surtensions Un interrupteur réarmable qui se déclenche quand un circuit est surchargé ou court circuite Cordon de Connexion Une prise électrique et une fiche câblée sur une longueur de cordon électrique flexible Continu Sortie La quantité d énergie produite en continu par opposition à la puissance maximale qui ne peut être produite que pendant de courte...

Page 4: ...ed fault status light IS illuminated a potential hazardous condition may exist Contact your electric utility or authorized installer 2 23 Please refer to page 22 for GenerLink testing while utility power is present Audible Alarm Audible Alarm This section only applies to GenerLink units equipped with optional surge protection Check the product label on unit collar for the model number Units with a...

Page 5: ... it off Once you turn off your generator GenerLink will automatically switch your home back to utility power GenerLink has a built in safety feature that prevents back feeding the generator s power into the utility lines eliminating hazardous conditions for you and for utility service personnel Q Does my utility meter continue to run when using GenerLink with my generator A No your utility meter w...

Page 6: ...sèdent différents types de prises selon le type de générateur le type de puissance fourni et la taille du générateur Certains générateurs sont conçus pour une sortie de seulement 120 volts ou seulement 240 volts aucun ne convient pour alimenter votre domicile via GenerLink Si votre générateur n a pas de prise secteur de 120 240 volts il ne convient pas à une utilisation avec GenerLink Recherchez l...

Page 7: ... D E Lights Wattage Number F G The Connection Cord Connection cords are typically 20 to 60 feet long with a maximum recommended length of 60 feet for a 50 amp circuit To determine the correct cord length follow these easy steps STEP 1 Select a location for your generator when it is being used with GenerLink Consult your generator manufacturers owner s manual for instructions on the acceptable plac...

Page 8: ... you to select the combination of loads appliances you want to operate by simply switching breakers in the household breaker panel This flexibility makes generator sizing easy CAUTION Do not turn on your home s heat pump or central air conditioning while using GenerLink The starting wattage for these devices exceeds GenerLink s 40 amp capacity 14 11 Remarques sur le Guide d Utilisation des Apparei...

Page 9: ... 50 amps GenerLink is designed to be compatible with 20 amp 30 amp and 50 amp connectors GenerLink is not rated to be compatible with larger current outputs and will electronically disconnect if you are generating outputs larger than 40 amps Appliance Usage Guide Appliance Usage Guide Equipment Water Heater 50 gallon Portable Heater with fan Furnace Fan Central 1 4 HP 1 3 HP 1 2 HP Computer Fax Ma...

Page 10: ...liance that you have selected multiply the starting factor by the run watts and write the results or the load watts in column E NOTE Only items that start simultaneously should be tallied in column D Finally sum up all of the load wattages for each appliance and lights in column E Add each appliances load watts and write the number in box G The number in box G represents the total amount of load y...

Page 11: ... D E Lights Wattage Number F G The Connection Cord Connection cords are typically 20 to 60 feet long with a maximum recommended length of 60 feet for a 50 amp circuit To determine the correct cord length follow these easy steps STEP 1 Select a location for your generator when it is being used with GenerLink Consult your generator manufacturers owner s manual for instructions on the acceptable plac...

Page 12: ...t to the utility To reconnect to your electric utility A Turn off your generator Expect to hear a clicking sound from the GenerLink unit when the power transition occurs This is a simple verification that normal utility service has been restored B On your breaker panel set all circuit breakers to the on position C You can now unplug the generator from GenerLink To unplug GenerLink gently pull down...

Page 13: ...ting procedures in the generator owner s manual and then start your generator STEP 6 If your GenerLink unit is NOT equipped with optional surge protection Model MA23 24 S please skip to Step 7 If after starting your generator the GenerLink unit begins emitting a constant audible alarm IT IS STILL SAFE TO OPERATE YOUR GENERATOR with GenerLink The alarm indicates that the surge protection components...

Page 14: ...ed fault status light IS illuminated a potential hazardous condition may exist Contact your electric utility or authorized installer 2 23 Please refer to page 22 for GenerLink testing while utility power is present Audible Alarm Audible Alarm This section only applies to GenerLink units equipped with optional surge protection Check the product label on unit collar for the model number Units with a...

Page 15: ... all the circuits fuses connect to the incoming electrical supply line from the utility Breakers See Circuit Breaker Capacity The amount of power expressed in watts kilowatts or megawatts that a device can provide at any given instant or The maximum load of electricity that equipment can carry Circuit A continuous loop of current Circuit Breaker The most common type of overcurrent protection A res...

Page 16: ...ctly or indirectly use operation or failure of the GenerLink unit TERMS TO BE EXCLUSIVE You acknowledge that the Terms and Conditions constitute the final and entire agreement regarding the use and purchase of the GenerLink device GOVERNING LAW It is expressly understood and agreed that the Terms and Conditions are to be interpreted according to the laws of the Georgia Copyright 2020 by Global Pow...