301 971
2010-11-18
|
Sicam srl società unipersonale
34 | JUMBO TCS60 | First start up
en
4.3 Pneumatic
connection
1.
Connect the JUMBO TCS60 to the compressed air
supply unit.
652001-07_Rf
2.
Adjust to a pressure between 8 and 12 bar.
Pull the red knurled screw (pressure reducing val-
ve) fi rst upwards and then twist it to adjust ope-
rating pressure.
Check pressure on the manometer.
4.4 Electrical
connection
1.
Check the correspondence of the mains tension and
the tension shown on the identification tag.
2.
Ask a qualified electrician to mount a connection
plug for single-phase or (depending on the tension
you have ordered ) three-phase current (see the
electrical connections diagram inside the electrical
panel).
i
The costs of arranging a mains protection device for
the plug are borne by the customer.
3.
Protect the JUMBO TCS60 according to specific
national rules.
4.5
Check rotation direction
Warning - malfunctioning danger!
The JUMBO TCS60 rotates counter-clockwise.
Turn off the main switch.
Check the part dedicated to functioning
anomalies to find the cause (see chap. 5.6)
For a correct functioning of JUMBO TCS60 it is extre-
mely important that after having connected and started
the machine the rotation direction corresponds to that
shown by the arrow on the control unit motor.
652117-14_Mi
Fig. 2:
Check rotation direction.