63
Description of defects,
external manifestations
and additional signs
Probable cause
Rectification method
4.
_
The level gauge does not
does not react to
pressing the keys. The same
note is displayed for a long
time.
Malfunctioning of
the
controller program
because
of unforeseen
situation, e.g.
in the level
determination
program
Restarting the device by
simultaneously pressing
the LEVEL and MODE
buttons (Supplement
14.1)
5. Loss of echograms when
transfering into the
computer
The non-volatile
storage has
been partly damaged.
To eliminate these
defects, the tool should
be repaired.