9/12/17, 9(22 AM
Shure Publications | User Guides | ANI22
Page 27 of 35
http://pubs.shure.com/guide/ANI22/en-US
AUX_LVL >
< REP
xx
AUDIO_OUT_LVL_SWITCH
MIC_LVL >
Flash Lights on ANI22
Command String:
< SET FLASH ON >
< SET FLASH OFF >
Send one of these commands to the ANI22.
The flash automatically turns off after 30
seconds.
ANI22 Response:
< REP FLASH ON >
< REP FLASH OFF >
The ANI22 will respond with one of these
strings.
Turn Metering On
Command String:
< SET METER_RATE
sssss
>
Where
sssss
is the metering speed in
milliseconds. Setting
sssss
=0 turns
metering off. Minimum setting is 100
milliseconds. Metering is off by default.
ANI22 Response:
< REP METER_RATE
sssss
>
< SAMPLE
aaa bbb ccc ddd
>
Where aaa, bbb, etc is the value of the
audio level received and is 000-060.
aaa
= input 1
bbb
= input 2
ccc
= output 1
ddd
= output 2
Stop Metering
Command String:
< SET METER_RATE 0 >
A value of 00000 is also acceptable.
ANI22 Response:
< REP METER_RATE 00000 >
Get LED Brightness
Command String:
< GET LED_BRIGHTNESS >
ANI22 Response:
< REP LED_BRIGHTNESS
n
>
Where
n
can take on the following values:
0 = LED disabled
1 = LED dim
2 = LED default
Set LED Brightness
Command String:
Where
n
can take on the following values: