GENERAL

The UNlDYNE

 III Model 545SD is a dual-impedance, uni-

directional, dynamic microphone. Shipped connected for low-
impedance operation, it features a silent magnetic reed on/off
switch.

The UNlDYNE III is a favorite for instrument pickup and re-

cording, and can be used on lecterns for public address sys-
tems such as those used in political conventions and legisla-
tures, convention halls, hotels, public auditoriums, stadiums,
schools, and churches.

FEATURES

Exceptionally uniform cardioid pattern minimizes feedback
in PA applications

Selectable dual–impedance operation

Silent magnetic reed on/off switch with lock option

Cardioid dynamic

Frequency response: 50 to 15,000 Hz

CONNECTIONS

When using the microphone with a balanced input, pins 2

and 3 are the audio signal carriers. When using the microphone
with an unbalanced input, use a cable wired with pin 2 as the sig-
nal carrier and pin 3 connected to the cable shield (ground),
such as the Shure C20HZ high-impedance cable.

IMPEDANCE SELECTION

The microphone is shipped connected for low impedance

operation. To change to high impedance, proceed as follows
(refer to Figure 1):

1.

Remove plug element at receptacle end of microphone by
turning slotted setscrew in (counterclockwise) and carefully
withdrawing plug element from case.

2.

Disconnect 2–terminal impedance selection socket from
rear of plug element.

3.

Reconnect 2–terminal impedance selection socket in re-
verse position so that pin 3 of plug element is inserted in
socket terminal “H” (White).

4.

Reassemble plug element into microphone and seal set-
screw securely by turning out (clockwise).

ÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎ

ÎÎÎÎÎÎÎÎÎ

IMPEDANCE

SELECTION SOCKET

PLUG
ELEMENT

SET SCREW

PIN 3

IMPEDANCE SELECTION—

RECEPTACLE END OF MICROPHONE

FIGURE 1

POLARITY

All cables and microphones should be tested to ensure

that they have the same polarity. To test two microphones
and/or their cables for proper polarity, connect them to an ampli-
fier and talk or sing into them while holding them three or four
inches apart. The sound from the speakers should be the same
when talking into either microphone or directly between them.
If the sound drops drastically, or if a dead spot is found when
talking between the two microphones, either the microphones
or their cables have opposite polarity.

To change the polarity of a microphone cable, either use

a Shure A15PRS phase reverser or interchange the wires con-
nected to pins 2 and 3 of the three-pin connector at one end of
the cable. To change the polarity of a microphone, the micro-
phone cartridge leads must be interchanged. This should be
performed by your dealer, the Shure Factory Service Depart-
ment, or other qualified service personnel.

SPECIFICATIONS

Type

Dynamic

Frequency Response

50 to 15,000 Hz (see Figure 2)

Polar Pattern

Cardioid (unidirectional)—uniform with frequency, sym-
metrical about axis (see Figure 3)

lmpedance

Dual. Microphone rating impedance is 150 ohms (250
ohms actual) for connection to microphone inputs rated
at 19 to 300 ohms and “High” for connection to high-im-
pedance microphone inputs.
Wired for low impedance as supplied. To change impe-
dance, see sections on lmpedance Selection and Con-
nections.

Output Level (at 1,000 Hz)

“L”

“H”

Open Circuit Voltage*

–58.0dB

–35.0 dB

. . . . . . . . . . 

(1.3 mV)

(17.6 mV)

 *0 dB = 1 volt per Pascal (1 Pa = 94 dB SPL)

Polarity

Positive pressure on diaphragm produces positive volt-
age on pin 2 (with respect to pin 3). See Figure 4.

 UNIDYNE

III MODEL 545SD

 USER GUIDE

27B3059 (TG)

2000, Shure Incorporated

Printed in U.S.A.

Summary of Contents for 545SD

Page 1: ...PLUG ELEMENT SET SCREW PIN 3 IMPEDANCE SELECTION RECEPTACLE END OF MICROPHONE FIGURE 1 POLARITY All cables and microphones should be tested to ensure that they have the same polarity To test two micro...

Page 2: ...ne shall be dual impedance with a rated impedance of 150 ohms for connection to micro phone inputs rated at 19 to 300 ohms and High for connection to high impedance microphone inputs lmpedance change...

Page 3: ...dance 2 bornes en position inverse en ins rant la broche 3 de l embase m le dans la borne H blanche de la prise 4 Remonter l embase XLR dans le microphone et fixer la vis d arr t en la serrant fond dr...

Page 4: ...SSOIRES FOURNIS Pince microphone A25D PI CES DE RECHANGE Capsule R45 Embase XLR m le RK169P cran et grille RPM210 ACCESSOIRES EN OPTION Transformateur d adaptation de ligne S rie A95 Socle de pupitre...

Page 5: ...H Wei eingesteckt wird 4 Das Steckelement wieder in das Mikrofon einbauen und die Stellschraube sicher festziehen indem sie nach au en im Uhrzeigersinn gedreht wird PIN 3 STELLSCHRAUBE STECKELEMENT I...

Page 6: ...82 1 1992 MITGELIEFERTES ZUBEH R Schwenkadapter A25D ERSATZTEILE Kapsel R45 Steckelement RK169P Filter und Grill RPM210 SONDERZUBEH R Leistungsanpassungs bertrager Serie A95 Tischstativ S37A S39A Isol...

Page 7: ...do su posici n de manera que la clavija 3 del elemento del enchufe se inserte en el borne H blan co del puente 4 Vuelva a instalar el elemento del enchufe en el micr fono y selle el tornillo de fijaci...

Page 8: ...25D REPUESTOS C psula R45 Elemento del enchufe RK169P Malla y rejilla RPM210 ACCESORIOS OPCIONALES Transformador de impedancia Serie A95 Pedestal de escritorio S37A S39A Montaje con aislamiento A55M M...

Page 9: ...in modo che il piedino 3 del connettore sia inserito nel terminale H bian co dello zoccolo 4 Reinserite il connettore nel microfono e avvitate bene la vite di fermo girandola in senso orario VITE DI F...

Page 10: ...do A25D PARTI DI RICAMBIO Capsula R45 Connettore RK169P Schermo e griglia RPM210 ACCESSORI OPZIONALI Trasformatore per adattamento all impedenza di rete Serie A95 Sostegno da tavolo S37A S39A Sostegno...

Page 11: ......

Page 12: ...ww shure com 222 Hartrey Avenue Evanston IL 60202 3696 U S A Phone 847 866 2200 Fax 847 866 2279 In Europe Phone 49 7131 72140 Fax 49 7131 721414 In Asia Phone 852 2893 4290 Fax 852 2893 4055 Elsewher...