Truss Booster RDM 1-6 

 

 

 

Problem 

Probable cause(s) 

Solution 

One or more 
fixtures do not 
function at all. 

No power to the fixture. 

 

Check if power is switched on 
and cables are plugged in. 

Primary fuse blown. 

 

Replace fuse. 

Fixtures reset 
correctly, but all 
respond 
erratically or not 
at all to the 
controller. 

The controller is not connected. 

 

Connect controller. 

5-pin XLR Out of the controller 
does not match XLR In of the first 
fixture on the link (i.e. signal is 
reversed). 

 

Install a phase reversing cable 
between the controller and the 
first fixture on the link. 

Fixtures reset 
correctly, but 
some respond 
erratically or not 
at all to the 
controller. 

Poor data quality. 

 

Check data quality. If much lower 
than 100 percent, the problem 
may be a bad data link 
connection, poor quality or 
broken cables, missing 
termination plug, or a defective 
fixture disturbing the link. 

Bad data link connection. 

 

Inspect connections and cables. 
Correct poor connections. Repair 
or replace damaged cables. 

Data link not terminated with 120 
Ohm termination plug. 

 

Insert termination plug in output 
jack of the last fixture on the link. 

One of the fixtures is defective and 
disturbs data transmission on the 
link. 

 

Bypass one fixture at a time until 
normal operation is restored: 
unplug both connectors and 
connect them directly together. 

 

Have the defective fixture 
serviced by a qualified 
technician.  

5-pin XLR Out on the fixtures does 
not match (pins are reversed). 

 

Install a phase-reversing cable 
between the fixtures or swap pins 
in the fixture that behaves 
erratically. 

No light or 
lamps/LEDs cut 
out intermittently. 

Fixture is too hot. 

 

Allow the fixture to cool down. 

 

Turn up the air conditioning. 

Lamps/LEDs damaged. 

 

Disconnect the defective fixture 
and return it to the fixture’s 
dealer. 

The power supply settings do not 
match local AC voltage and 
frequency. 

 

Disconnect fixture. Check settings 
and correct if necessary. 

Summary of Contents for Truss Booster RDM 1-6

Page 1: ...Truss Booster RDM 1 6 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 50794 MANUAL ENGLISH...

Page 2: ...ins 5 Return Procedure 6 Claims 6 Description of the device 7 Overview 7 Front 8 Back 9 Installation 9 Setup and Operation 9 Control Modes 10 Multiple Truss Boosters DMX RDM control 10 Fixture Linking...

Page 3: ...ncludes Showtec Truss Booster RDM 1 6 Pro power cable 1 5 m 1 x mounting bracket 2 x Velcro strap User manual Safety Instructions Every person involved with the installation operation and maintenance...

Page 4: ...power from the mains when device is not used or before cleaning Only handle the power cord by the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to ex...

Page 5: ...the safety of others Improper installation can cause serious damage to people and property Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety...

Page 6: ...ion with the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YE...

Page 7: ...one number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform th...

Page 8: ...ed bracket or Velcro straps The rubber protection rings on each side of the rugged housing makes this booster ideal for road productions Input voltage 100 240 V AC 50 60 Hz Power consumption 5 W Housi...

Page 9: ...X 512 protocol that allows bi directional communication between a lighting controller and RDM compliant devices 05 LED power indicator 06 100 240 V pro power connector OUT Gray 07 100 240 V pro power...

Page 10: ...connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Setup and Operation Follow the direction...

Page 11: ...s shown in Fig 04 Connect the first unit s DMX thru socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth unit 06 Connect light fixtu...

Page 12: ...your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DAP Audio DMX Data Cables DAP Audio Basic microphone cable for allr...

Page 13: ...ype and specification See the product specification label for details Troubleshooting No Light If the light effect does not operate properly refer servicing to a technician Suspect three potential pro...

Page 14: ...xture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Inser...

Page 15: ...Control protocols DMX 512 RDM Connections Pro power connector IN Blue OUT Gray 1 x 5 pin DMX RDM IN 1 x 5 pin DMX RDM THRU 6 x 5 pin DMX RDM OUT Housing Metal flame retardant plastic Fuse T1AL 250V Di...

Page 16: ...2019 Showtec...

Reviews: