background image

 

  

 

 

   

 

Ordercode: 50794 

Truss Booster RDM 1-6 

Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

To eliminate wear and improve lifespan, during periods of non-use, completely disconnect from 
power via breaker or by unplugging. 

 

The maximum ambient temperature ta = 40 °C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 40 °C. 

 

If this device is operated in any other way, than the one described in this manual, the product may 
suffer damages and the warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash, etc. 

 

You endanger your own safety and the safety of others! 

 

Improper installation can cause serious damage to people and property!

 

 

Rigging 
Please follow the European and national guidelines concerning rigging, trussing and all 
other safety issues. 

 

Do not attempt the installation yourself ! 
Always let the installation be carried out by an authorized dealer ! 

 

Procedure: 

 

If the Truss Booster is lowered from the ceiling or high joists, professional trussing systems have to be 
used. 

 

Use a clamp to mount the Truss Booster, with the mounting bracket, to the trussing system. 

 

The Truss Booster must never be fixed swinging freely in the room.  

 

The installation must always be secured with a safety attachment, e.g. an appropriate safety net or 
safety cable. 

 

When rigging, derigging or servicing the Truss Booster, always make sure, that the area below the 
installation site is secured and that there are not any unauthorized people around. 

 

Improper installation can cause serious injuries and/or damage of property! 

 

Summary of Contents for Truss Booster RDM 1-6

Page 1: ...Truss Booster RDM 1 6 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 50794 MANUAL ENGLISH...

Page 2: ...ins 5 Return Procedure 6 Claims 6 Description of the device 7 Overview 7 Front 8 Back 9 Installation 9 Setup and Operation 9 Control Modes 10 Multiple Truss Boosters DMX RDM control 10 Fixture Linking...

Page 3: ...ncludes Showtec Truss Booster RDM 1 6 Pro power cable 1 5 m 1 x mounting bracket 2 x Velcro strap User manual Safety Instructions Every person involved with the installation operation and maintenance...

Page 4: ...power from the mains when device is not used or before cleaning Only handle the power cord by the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to ex...

Page 5: ...the safety of others Improper installation can cause serious damage to people and property Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety...

Page 6: ...ion with the mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YE...

Page 7: ...one number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform th...

Page 8: ...ed bracket or Velcro straps The rubber protection rings on each side of the rugged housing makes this booster ideal for road productions Input voltage 100 240 V AC 50 60 Hz Power consumption 5 W Housi...

Page 9: ...X 512 protocol that allows bi directional communication between a lighting controller and RDM compliant devices 05 LED power indicator 06 100 240 V pro power connector OUT Gray 07 100 240 V pro power...

Page 10: ...connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Setup and Operation Follow the direction...

Page 11: ...s shown in Fig 04 Connect the first unit s DMX thru socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth unit 06 Connect light fixtu...

Page 12: ...your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DAP Audio DMX Data Cables DAP Audio Basic microphone cable for allr...

Page 13: ...ype and specification See the product specification label for details Troubleshooting No Light If the light effect does not operate properly refer servicing to a technician Suspect three potential pro...

Page 14: ...xture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Inser...

Page 15: ...Control protocols DMX 512 RDM Connections Pro power connector IN Blue OUT Gray 1 x 5 pin DMX RDM IN 1 x 5 pin DMX RDM THRU 6 x 5 pin DMX RDM OUT Housing Metal flame retardant plastic Fuse T1AL 250V Di...

Page 16: ...2019 Showtec...

Reviews: