background image

 

  

 

 

   

 

Ordercode: 30774 

Stage Blinder 8 DMX 

 

 

 
 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 
 

 

Summary of Contents for Stage Blinder 4 DMX Black

Page 1: ...Stage Blinder 8 DMX V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 30774 MANUAL ENGLISH...

Page 2: ...nstalling the Lamp 8 Set Up and Operation 8 Control Modes 9 One Stage Blinder Auto Mode 9 One Stage Blinder Manual Mode 9 Multiple Stage Blinders DMX control 10 DIP Switch Setting for DMX Mode 11 DMX...

Page 3: ...ipment includes Showtec Stage Blinder 8 DMX with a fixed power cable without a plug 1 m User manual Safety Instructions Every person involved with the installation operation and maintenance of this de...

Page 4: ...the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged C...

Page 5: ...ections carried out by an authorized dealer Procedure If the Stage Blinder is lowered from the ceiling or high joists professional trussing systems have to be used Use a clamp to mount the Stage Blind...

Page 6: ...e number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this...

Page 7: ...ontrol modes Auto Manual DMX Dimmer 0 100 Housing Aluminum Color Black Connections fixed cable without plug 3 pin XLR IN OUT IP rating IP 20 Fuse T10AL 250V Dimensions 485 x 84 x 810 mm LxWxH Weight 1...

Page 8: ...DIP switches on the left control panel 06 you can control sections G1 and G2 By flipping the DIP switches on the right control panel 07 you can control sections G3 and G4 Fig 03 Installation Remove a...

Page 9: ...arranty Procedure 01 Loosen the 2 screws on the front of the lamp housing 02 Gently remove the metal lamp housing 03 Read lamp instructions Do not touch the lamp bulb glass Gently remove the lamp from...

Page 10: ...s 1 8 to set the fade speed DIP switch 1 ON fastest fade speed DIP switch 8 ON slowest fade speed One Stage Blinder Manual Mode 01 Fasten the effect light to a firm trussing Leave at least 0 5 meter o...

Page 11: ...0 to OFF Flip the DIP switches 1 9 to set the desired DMX address See pages 11 12 for more information The pins 01 Earth 02 Signal 03 Signal 06 Link the units as shown in fig 05 Connect the first unit...

Page 12: ...lanation Since each unit has 2 channels each address advances by 2 values See Address Value above Once the address values have been determined add DIP switch values to obtain the appropriate address D...

Page 13: ...12 Ordercode 30774 Stage Blinder 8 DMX DMX Address Quick Reference Chart...

Page 14: ...tly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic...

Page 15: ...and a soft cloth Do not use alcohol or solvents The lamps will require weekly cleaning as smoke fluid tends to build up residues reducing the light output very quickly Please clean internal components...

Page 16: ...he fuse 04 If all of the above appears to be O K plug the unit in again 05 If you are unable to determine the cause of the problem do not open the Stage Blinder as this may damage the unit and the war...

Page 17: ...connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the...

Page 18: ...Electro mechanical effects Light source 8 x Par 36 120V 650W DWE Dimmer 0 100 Housing Aluminum Color Black IP rating IP 20 DMX control via standard DMX controller Onboard 2 x DIP switch control panel...

Page 19: ...18 Ordercode 30774 Stage Blinder 8 DMX Dimensions...