14 

   

 

Ordercode: 30774 

Stage Blinder 8 DMX 

Maintenance 

The operator has to make sure that safety-related and machine-technical installations are to be 
inspected by an expert after every year in the course of an acceptance test. 
The operator has to make sure that safety-related and machine-technical installations are to be 
inspected by a skilled person once a year. 
 
The following points have to be considered during the inspection: 
01)

 

All screws used for installing the device or parts of the device have to be tightly connected and 
must not be corroded. 

02)

 

There may not be any deformations on housings, fixations and installation spots. 

03)

 

Mechanically moving parts like axles, eyes and others may not show any traces of wearing. 

04)

 

The electric power supply cables must not show any damages or material fatigue. 

 

The Stage Blinder requires almost no maintenance. However, you should keep the unit clean.  
Otherwise, the fixture’s light output will be significantly reduced. Disconnect the mains power supply, and 
then wipe the cover with a damp cloth. Do not immerse in liquid. Wipe lamps clean with glass cleaner 
and a soft cloth. Do not use alcohol or solvents. 
The lamps will require weekly cleaning, as smoke-fluid tends to build up residues, reducing the light 
output very quickly. 
Please clean internal components once a year with a light brush and vacuum cleaner.  
Keep connections clean. Disconnect electric power, and then wipe the DMX connections with a damp 
cloth. Make sure connections are thoroughly dry before linking equipment or supplying electric power. 
 

Changing the Lamp

 

01)

 

Disconnect mains power supply. Loosen the 2 screws on the back of the housing. 

02)

 

Follow directions for installing a new lamp, page 8. 

 

Replacing the Fuse

 

Power surges, short-circuit or inappropriate electrical power supply may cause a fuse to burn out. If the 
fuse burns out, the product will not function whatsoever. If this happens, follow the directions below: 
01)

 

Unplug the unit from electric power source. 

02)

 

Insert a flat-head screwdriver into a slot in the fuse cover. Turn the screwdriver to the left, at the same 
time gently push a bit (Turn and Push). The fuse will come out. 

03)

 

Remove the used fuse. If brown or unclear, it is burned out. 

04)

 

Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse cover. Be sure to 
use a fuse of the same type and specification. See the product specification label for details. 

 

 

Summary of Contents for Stage Blinder 4 DMX Black

Page 1: ...Stage Blinder 8 DMX V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 30774 MANUAL ENGLISH...

Page 2: ...nstalling the Lamp 8 Set Up and Operation 8 Control Modes 9 One Stage Blinder Auto Mode 9 One Stage Blinder Manual Mode 9 Multiple Stage Blinders DMX control 10 DIP Switch Setting for DMX Mode 11 DMX...

Page 3: ...ipment includes Showtec Stage Blinder 8 DMX with a fixed power cable without a plug 1 m User manual Safety Instructions Every person involved with the installation operation and maintenance of this de...

Page 4: ...the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged C...

Page 5: ...ections carried out by an authorized dealer Procedure If the Stage Blinder is lowered from the ceiling or high joists professional trussing systems have to be used Use a clamp to mount the Stage Blind...

Page 6: ...e number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this...

Page 7: ...ontrol modes Auto Manual DMX Dimmer 0 100 Housing Aluminum Color Black Connections fixed cable without plug 3 pin XLR IN OUT IP rating IP 20 Fuse T10AL 250V Dimensions 485 x 84 x 810 mm LxWxH Weight 1...

Page 8: ...DIP switches on the left control panel 06 you can control sections G1 and G2 By flipping the DIP switches on the right control panel 07 you can control sections G3 and G4 Fig 03 Installation Remove a...

Page 9: ...arranty Procedure 01 Loosen the 2 screws on the front of the lamp housing 02 Gently remove the metal lamp housing 03 Read lamp instructions Do not touch the lamp bulb glass Gently remove the lamp from...

Page 10: ...s 1 8 to set the fade speed DIP switch 1 ON fastest fade speed DIP switch 8 ON slowest fade speed One Stage Blinder Manual Mode 01 Fasten the effect light to a firm trussing Leave at least 0 5 meter o...

Page 11: ...0 to OFF Flip the DIP switches 1 9 to set the desired DMX address See pages 11 12 for more information The pins 01 Earth 02 Signal 03 Signal 06 Link the units as shown in fig 05 Connect the first unit...

Page 12: ...lanation Since each unit has 2 channels each address advances by 2 values See Address Value above Once the address values have been determined add DIP switch values to obtain the appropriate address D...

Page 13: ...12 Ordercode 30774 Stage Blinder 8 DMX DMX Address Quick Reference Chart...

Page 14: ...tly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic...

Page 15: ...and a soft cloth Do not use alcohol or solvents The lamps will require weekly cleaning as smoke fluid tends to build up residues reducing the light output very quickly Please clean internal components...

Page 16: ...he fuse 04 If all of the above appears to be O K plug the unit in again 05 If you are unable to determine the cause of the problem do not open the Stage Blinder as this may damage the unit and the war...

Page 17: ...connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the...

Page 18: ...Electro mechanical effects Light source 8 x Par 36 120V 650W DWE Dimmer 0 100 Housing Aluminum Color Black IP rating IP 20 DMX control via standard DMX controller Onboard 2 x DIP switch control panel...

Page 19: ...18 Ordercode 30774 Stage Blinder 8 DMX Dimensions...

Page 20: ...2016 Showtec...

Reviews: