IMPORTANT

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the device. 

 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 
connections with the mains with particular caution! 

 

Always disconnect power from the mains, when device is not used or before cleaning ! Only handle 
the power cord by the plug. Never pull out the plug by tugging the power cord. 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never aim the output nozzle directly at people. 

 

Never aim the output nozzle at open flames. 

 

Never add flammable liquids of any kind (oil, gas, perfume) to the haze liquid. 

 

Never drink haze liquid. If it is ingested, call a doctor immediately. If haze liquid comes in contact 
with skin or eyes, rinse thoroughly with water. 

 

Never lock haze-filled rooms. Risk: panic among the locked persons! 

 

Never use the device permanently! The output should be active only for short periods of time.  

 

Do not insert objects into air vents. 

 

Do not open the device and do not modify the device. 

 

Do not connect this device to a dimmer pack. 

 

Do not switch the device on and off in short intervals, as this would reduce the device’s life. 

 

Do not touch the hazer output bare-handed during its operation (output becomes very hot).  

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use device indoors, avoid contact with water or other liquids. 

 

Only use haze in well-ventilated rooms. 

 

Only use the high-quality MHL-hazer liquid, recommended by your dealer (ordercode: 

60569

). Other 

haze liquids may cause poor effect. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always make sure there is sufficient liquid in the haze liquid tank. 

 

Always allow free air space of at least 50 cm around the sides and top of the unit. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect device from the CO

2

 cylinder and the hose, when device is not used or before 

cleaning! Always handle the CO

2

 hose with care. Never pull out the CO

2

 hose by tugging. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that all the required safety devices are in good condition and function properly. 

 

Make sure that the CO

2

 hose is never crimped or damaged. Check the device and the CO

2

 hose 

from time to time. 

 

If text and/or icons are missing, damaged or illegible on the Mistique, they should be replaced 

 

Always drain tank before shipping or otherwise transporting this unit. 

 

Always keep tank cap closed while operating. 

 

Always keep the haze machine upright. 

 

Always unplug the Mistique before filling its tank. 

 

For adult use only. Haze machine must be installed out of the reach of children. Never leave the unit 
running unattended. Leave the grid guarding the nozzle in place if the machine is to be used in the 
presence of children 

 

Always keep the nozzle at least 50 cm away from contact with anything, while in operation. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power-
cord from time to time. 

 

Make sure that the core diameter of extension cords and power cords is sufficient for the required 
power consumption of the device. 

 

The cable insert or the female part in the device must never be strained. There must always be 
sufficient cable to the device. Otherwise, the cable may be damaged which may lead to deadly 
electrical shocks. 

 

If the external cable is damaged, it has to be replaced by a qualified technician. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

Summary of Contents for Mistique

Page 1: ...Mistique V2 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 60769 MANUAL ENGLISH...

Page 2: ...Cabling 17 Control Panel 18 Control Mode 18 DMX Addressing 18 Menu Overview 19 Main Menu Options 23 Status Menu 24 1 Timer 1 25 1 1 Interval 25 1 2 Duration 26 1 3 Output Level 26 1 4 Fan Level 27 2...

Page 3: ...5 Software Update 45 8 3 6 Keypad Sound 46 DMX Channels 47 1 channel 47 3 channels 47 5 channels 47 Maintenance 48 Automatic Cleaning Procedure 48 Automatic Protection Mechanism 48 Fan Cleaning 48 O R...

Page 4: ...acking Your shipment includes Mistique True1 pro power cable 1 5 m User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to be qualif...

Page 5: ...ufficient liquid in the haze liquid tank Always allow free air space of at least 50 cm around the sides and top of the unit Always allow free air space of at least 50 cm around the unit for ventilatio...

Page 6: ...the device The user is responsible for correct positioning and operating of the Mistique The manufacturer will not accept liability for unsafe situations accidents damages caused by The misuse or inco...

Page 7: ...the safety of others Showtec excludes liability for unsafe situations accidents and damage that are the result of Disregard for the warnings or regulations as set out on the Mistique or in this manua...

Page 8: ...ber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this chec...

Page 9: ...ouchscreen Control Mode Manual mode 2x Timer mode DMX control Wireless DMX control DMX Mode 1 3 5 channels Colour Black Housing Metal Flame retardant plastic Data Connection Neutrik XLR 5 pin 3 pin IN...

Page 10: ...ntside Fig 01 01 Fan 02 Plug with adapter for power to the fan 03 Output nozzle 04 Carry handle 05 MHL fluid tank 2 5 L Note You can only fill 75 of the tank due to compression that is not more than 2...

Page 11: ...psi 3 4 to 4 1 bar max Quick lock coupling 12 100 240 V True1 pro power connector OUT 13 Automatic Fuse 8A 250V 14 Menu ON OFF Press and hold down for 3 seconds to activate the menu You can check chan...

Page 12: ...on The maximum inclination angle of the device should not exceed 30 Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to...

Page 13: ...than 2 L in the tank Note Running a haze machine with no hazer liquid can permanently damage the unit Note Never shut down the Mistique while making haze Note The Mistique needs a CO2 connection with...

Page 14: ...he device must always be placed in a horizontal position The maximum inclination angle of the device should not exceed 30 01 Loosen the cap on the fluid tank 05 and remove it 02 Insert a funnel into t...

Page 15: ...is not more than 2 L in the tank 03 Connect the Machine air in to the pressure regulator with gas tank and open the adjuster valve between 50 60 psi 3 5 4 1 bar or 350 410 kPa position 04 Plug the pow...

Page 16: ...60769 Mistique 10 Close the CO2 now 11 The counter will count down from 10 to zero 12 Let the Mistique decompress and please wait until the pressure is down 13 Now you can decouple the CO2 hose and th...

Page 17: ...circulation 02 Plug the end of the electric mains power cord into a proper electric power supply socket 03 Use a 3 pin 5 pin XLR cable to connect the Mistiques and other devices 04 Link the units as s...

Page 18: ...es together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use...

Page 19: ...X address of the second Mistique should be 1 5 6 006 the DMX address of the third Mistique should be 6 5 11 011 etc Please be sure that you do not have any overlapping channels in order to control eac...

Page 20: ...19 Ordercode 60769 Mistique Menu Overview...

Page 21: ...20 Ordercode 60769 Mistique...

Page 22: ...21 Ordercode 60769 Mistique...

Page 23: ...22 Ordercode 60769 Mistique...

Page 24: ...23 Ordercode 60769 Mistique Main Menu Options Timer 1 Timer 2 DMX Mode Power OFF Manual Mode Clean Mode Heater Menu...

Page 25: ...the status of your Mistique 1 Heater temperature percentage 2 Output pressure value 3 WDMX signal strength Ready Heating coil is on detected pressure error Temperature error detected pressure error Co...

Page 26: ...to start hazing with the current settings or press CONFIG to adjust them 04 If you have chosen CONFIG press UP DOWN to choose one of the 4 settings Interval Duration Output Level Fan Level 1 1 Interva...

Page 27: ...to adjust the timer duration The adjustment range is between 1 200 min 03 Press CONFIRM to confirm your setting 1 3 Output Level 01 Press CONFIRM to enter the output level menu 02 Press UP DOWN to adj...

Page 28: ...WN to adjust the fan level The adjustment range is between 20 100 03 Press CONFIRM to confirm your setting 2 Timer 2 With this menu you can set the Timer settings for Timer 2 For setup options please...

Page 29: ...1 Press to open the menu 02 The next window will show the current settings 03 Press CONFIG to adjust the current settings 04 If you have chosen CONFIG press UP DOWN to choose one of the 4 settings Add...

Page 30: ...between 1 511 If you choose the 3 CH configuration the adjustment range is between 1 509 If you choose the 5CH configuration the adjustment range is between 1 507 03 Press to confirm your setting 3 2...

Page 31: ...t one of the 2 modes Wireless Wired 03 Press CONFIRM to confirm your setting 3 4 Wireless Mode 01 Press CONFIRM to enter the wireless menu 02 Press UP DOWN to select the wireless unlink 03 Press CONFI...

Page 32: ...will show 03 Close the CO2 now 04 The counter will count down from 10 to zero 05 Let the Mistique decompress and please wait until the pressure is down 06 Now you can decouple the CO2 hose and the pow...

Page 33: ...ss UP DOWN to adjust the output level The adjustment range is between 5 40 psi 03 Press CONFIRM to confirm your setting 5 2 Fan Level 01 Press CONFIRM to enter the fan level menu 02 Press UP DOWN to a...

Page 34: ...window will show 03 Press CONFIRM to start the cleaning process 04 Once the countdown reaches 0 00 cleaning is finished and the Mistique machine is ready for use 7 Heater With this menu you can start...

Page 35: ...rdercode 60769 Mistique Heater is ON but Mistique is not ready to haze Heater is ON and Mistique is ready to haze 05 If you press START button again the heating process will stop and the display will...

Page 36: ...gs 01 Press the to open the menu 02 Press the UP DOWN buttons to choose one of the 3 settings DMX Setup Information Setting 8 1 DMX Setup 01 Press CONFIRM to enter the DMX Setup menu 02 Press the UP D...

Page 37: ...between 1 511 If you choose the 3CH configuration the adjustment range is between 1 509 If you choose the 5CH configuration the adjustment range is between 1 507 03 Press to confirm your setting 8 1 2...

Page 38: ...t one of the 2 modes Wireless Wired 03 Press CONFIRM to confirm your setting 8 1 4 Wireless Mode 01 Press CONFIRM to enter the wireless menu 02 Press UP DOWN to select the wireless unlink 03 Press CON...

Page 39: ...ormation menu 02 Press the UP DOWN buttons to choose one of the 5 settings Software Version Wireless Signal Temperature Pressure Operating Hours 8 2 1 Software Version 01 Press CONFIRM to enter the So...

Page 40: ...IRM to enter the Wireless Signal menu 02 The next window will show the problems if the wireless connection had been lost or show the signal strength of your Wi Fi signal Problems wireless signal W DMX...

Page 41: ...nal strength 8 2 3 Temperature 01 Press CONFIRM to enter the Temperature menu 02 The next window will show you the current heater temperature 8 2 4 Pressure 01 Press CONFIRM to enter the Pressure menu...

Page 42: ...g Hours menu 02 The next window will show the total operating hours of your Mistique hazer 8 3 Setting 01 Press CONFIRM to enter the Information menu 02 Press the UP DOWN buttons to choose one of the...

Page 43: ...one of the 4 backlight modes Auto Off Low Normal High 04 Press CONFIRM to confirm your setting 8 3 2 Auto Start 01 Press CONFIRM to enter the Auto Start menu 02 Press UP DOWN to select one of the 2 mo...

Page 44: ...3 Ordercode 60769 Mistique 8 3 3 Factory Reset 01 Press CONFIRM to enter the Factory Reset menu 02 The next window will show 03 Press CONFIRM to confirm your setting 04 The device will now reset itsel...

Page 45: ...44 Ordercode 60769 Mistique 8 3 4 Language 01 Press CONFIRM to enter the Language menu 02 Press UP DOWN to select one of the 2 language modes EN ZH 03 Press CONFIRM to confirm your setting...

Page 46: ...tware Update 01 It is not possible to update the Mistique without contacting your dealer 02 Press CONFIRM to enter the Software Update menu 03 The next window will show 04 Press CONFIRM to go to the n...

Page 47: ...newer software version exists 08 If so send the device back to your dealer to have it updated 09 Press CONFIRM to confirm your setting 8 3 6 Keypad Sound 01 Press CONFIRM to enter the Keypad Sound me...

Page 48: ...Fan Speed 0 4 Off 5 255 5 40 psi Channel 3 Heating 0 127 Off 128 255 On 5 channels Channel 1 Output volume 0 4 Off 5 255 5 40 psi Channel 2 Fan Speed 0 4 Off 5 255 5 40 psi Channel 3 Heating 0 127 Of...

Page 49: ...Note Haze machines may sputter small amounts of haze occasionally during operation and for a about a minute after being turned off The device will use the automatically start the auto clean function...

Page 50: ...have to replace the fuse on this device as the fuse T8A 250 V is automatic 01 Unplug the unit from electric power source 02 In case of a power surge short circuit or inappropriate power supply press t...

Page 51: ...f the Mistique does not operate properly refer servicing to a technician 01 If you experience low output or no output at all unplug immediately 02 Check liquid level and power from the wall 03 If all...

Page 52: ...ft min Warm up time 6 min Automatic fuse 8A 250V Dimensions 503 x 334 x 310 mm LxWxH Weight 17 kg Electro mechanical effects Mounting Mounting bracket Housing Metal Flame retardant plastic Power conne...