The Mistique requires almost no maintenance. However, you should keep the unit clean. Disconnect the 
mains power supply and then wipe the cover with a damp cloth. Wipe the front panel with a damp 
cloth. Do not use alcohol or solvents. Do not immerse in liquid.  
Keep connections clean. Disconnect electric power, and then wipe the connections with a damp cloth. 
Make sure connections are thoroughly dry before linking equipment or supplying electric power. 
 
Do not allow the MHL-2 haze liquid to become contaminated. Always place the cap back on the haze 
liquid container and the haze machine liquid tank immediately after filling. 
After every 40 hours of continuous operation, it is recommended to run a cleaning cycle. 
 

Automatic Cleaning Procedure 

This device is equipped with an automatic pipe cleaning feature. It automatically cleans the residues in 
the pipes after each use. Hence it can significantly prevents the chances of clogging and prolongs the 
machine’s product life cycle.  
The standard cleaning cycle will take a few minutes. Therefore, do not turn off the device immediately 
after operating the device.  
The automatic pipe cleaning procedure takes about 1 minute, whilst manually cleaning the device takes 
about 3 minutes. 
 

Performance

 

Note:

 

Haze machines may sputter small amounts of haze occasionally during operation and for a about a 
minute after being turned off. 
The device will use the automatically start the auto-clean function. 
 

Automatic Protection Mechanism 

This device is equipped with an automatic Fail-Safe system to protect the haze machine. 
01)

 

The Mistique will only start operating when the heater reaches its working temperature, otherwise it 
remains in standby modus. 

02)

 

If an error occurs, the LCD display will show an error message (please see page 50) and stop working 
until the error is cleared. 

03)

 

When the device overheats (up to 390 °C), the system will shut down and lock up. Please turn OFF 
the device and stop working until the error is cleared. 

04)

 

The device will automatically show a reminder message on the LCD display when the pressure runs 
low (display low pressure). Please replace the gas bottle when this message appears. 

05)

 

The device comes with a de-pressure valve. The purpose of this device is to control the pressure of 
the machine’s working temperature and prevent it from damage. 

 
When the device stops working for unknown reasons, please check the message on the LCD display. 
Then turn off the device for 30–60 seconds before turning it back on for a simple reset. If it is still not 
working, please contact your dealer and send it back to your dealer for further testing and service. 
 

Fan Cleaning 

Please clean the fan after a period of extensive use with a brush and compressed air. 
 

 

Summary of Contents for Mistique

Page 1: ...Mistique V2 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 60769 MANUAL ENGLISH...

Page 2: ...Cabling 17 Control Panel 18 Control Mode 18 DMX Addressing 18 Menu Overview 19 Main Menu Options 23 Status Menu 24 1 Timer 1 25 1 1 Interval 25 1 2 Duration 26 1 3 Output Level 26 1 4 Fan Level 27 2...

Page 3: ...5 Software Update 45 8 3 6 Keypad Sound 46 DMX Channels 47 1 channel 47 3 channels 47 5 channels 47 Maintenance 48 Automatic Cleaning Procedure 48 Automatic Protection Mechanism 48 Fan Cleaning 48 O R...

Page 4: ...acking Your shipment includes Mistique True1 pro power cable 1 5 m User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to be qualif...

Page 5: ...ufficient liquid in the haze liquid tank Always allow free air space of at least 50 cm around the sides and top of the unit Always allow free air space of at least 50 cm around the unit for ventilatio...

Page 6: ...the device The user is responsible for correct positioning and operating of the Mistique The manufacturer will not accept liability for unsafe situations accidents damages caused by The misuse or inco...

Page 7: ...the safety of others Showtec excludes liability for unsafe situations accidents and damage that are the result of Disregard for the warnings or regulations as set out on the Mistique or in this manua...

Page 8: ...ber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this chec...

Page 9: ...ouchscreen Control Mode Manual mode 2x Timer mode DMX control Wireless DMX control DMX Mode 1 3 5 channels Colour Black Housing Metal Flame retardant plastic Data Connection Neutrik XLR 5 pin 3 pin IN...

Page 10: ...ntside Fig 01 01 Fan 02 Plug with adapter for power to the fan 03 Output nozzle 04 Carry handle 05 MHL fluid tank 2 5 L Note You can only fill 75 of the tank due to compression that is not more than 2...

Page 11: ...psi 3 4 to 4 1 bar max Quick lock coupling 12 100 240 V True1 pro power connector OUT 13 Automatic Fuse 8A 250V 14 Menu ON OFF Press and hold down for 3 seconds to activate the menu You can check chan...

Page 12: ...on The maximum inclination angle of the device should not exceed 30 Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to...

Page 13: ...than 2 L in the tank Note Running a haze machine with no hazer liquid can permanently damage the unit Note Never shut down the Mistique while making haze Note The Mistique needs a CO2 connection with...

Page 14: ...he device must always be placed in a horizontal position The maximum inclination angle of the device should not exceed 30 01 Loosen the cap on the fluid tank 05 and remove it 02 Insert a funnel into t...

Page 15: ...is not more than 2 L in the tank 03 Connect the Machine air in to the pressure regulator with gas tank and open the adjuster valve between 50 60 psi 3 5 4 1 bar or 350 410 kPa position 04 Plug the pow...

Page 16: ...60769 Mistique 10 Close the CO2 now 11 The counter will count down from 10 to zero 12 Let the Mistique decompress and please wait until the pressure is down 13 Now you can decouple the CO2 hose and th...

Page 17: ...circulation 02 Plug the end of the electric mains power cord into a proper electric power supply socket 03 Use a 3 pin 5 pin XLR cable to connect the Mistiques and other devices 04 Link the units as s...

Page 18: ...es together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use...

Page 19: ...X address of the second Mistique should be 1 5 6 006 the DMX address of the third Mistique should be 6 5 11 011 etc Please be sure that you do not have any overlapping channels in order to control eac...

Page 20: ...19 Ordercode 60769 Mistique Menu Overview...

Page 21: ...20 Ordercode 60769 Mistique...

Page 22: ...21 Ordercode 60769 Mistique...

Page 23: ...22 Ordercode 60769 Mistique...

Page 24: ...23 Ordercode 60769 Mistique Main Menu Options Timer 1 Timer 2 DMX Mode Power OFF Manual Mode Clean Mode Heater Menu...

Page 25: ...the status of your Mistique 1 Heater temperature percentage 2 Output pressure value 3 WDMX signal strength Ready Heating coil is on detected pressure error Temperature error detected pressure error Co...

Page 26: ...to start hazing with the current settings or press CONFIG to adjust them 04 If you have chosen CONFIG press UP DOWN to choose one of the 4 settings Interval Duration Output Level Fan Level 1 1 Interva...

Page 27: ...to adjust the timer duration The adjustment range is between 1 200 min 03 Press CONFIRM to confirm your setting 1 3 Output Level 01 Press CONFIRM to enter the output level menu 02 Press UP DOWN to adj...

Page 28: ...WN to adjust the fan level The adjustment range is between 20 100 03 Press CONFIRM to confirm your setting 2 Timer 2 With this menu you can set the Timer settings for Timer 2 For setup options please...

Page 29: ...1 Press to open the menu 02 The next window will show the current settings 03 Press CONFIG to adjust the current settings 04 If you have chosen CONFIG press UP DOWN to choose one of the 4 settings Add...

Page 30: ...between 1 511 If you choose the 3 CH configuration the adjustment range is between 1 509 If you choose the 5CH configuration the adjustment range is between 1 507 03 Press to confirm your setting 3 2...

Page 31: ...t one of the 2 modes Wireless Wired 03 Press CONFIRM to confirm your setting 3 4 Wireless Mode 01 Press CONFIRM to enter the wireless menu 02 Press UP DOWN to select the wireless unlink 03 Press CONFI...

Page 32: ...will show 03 Close the CO2 now 04 The counter will count down from 10 to zero 05 Let the Mistique decompress and please wait until the pressure is down 06 Now you can decouple the CO2 hose and the pow...

Page 33: ...ss UP DOWN to adjust the output level The adjustment range is between 5 40 psi 03 Press CONFIRM to confirm your setting 5 2 Fan Level 01 Press CONFIRM to enter the fan level menu 02 Press UP DOWN to a...

Page 34: ...window will show 03 Press CONFIRM to start the cleaning process 04 Once the countdown reaches 0 00 cleaning is finished and the Mistique machine is ready for use 7 Heater With this menu you can start...

Page 35: ...rdercode 60769 Mistique Heater is ON but Mistique is not ready to haze Heater is ON and Mistique is ready to haze 05 If you press START button again the heating process will stop and the display will...

Page 36: ...gs 01 Press the to open the menu 02 Press the UP DOWN buttons to choose one of the 3 settings DMX Setup Information Setting 8 1 DMX Setup 01 Press CONFIRM to enter the DMX Setup menu 02 Press the UP D...

Page 37: ...between 1 511 If you choose the 3CH configuration the adjustment range is between 1 509 If you choose the 5CH configuration the adjustment range is between 1 507 03 Press to confirm your setting 8 1 2...

Page 38: ...t one of the 2 modes Wireless Wired 03 Press CONFIRM to confirm your setting 8 1 4 Wireless Mode 01 Press CONFIRM to enter the wireless menu 02 Press UP DOWN to select the wireless unlink 03 Press CON...

Page 39: ...ormation menu 02 Press the UP DOWN buttons to choose one of the 5 settings Software Version Wireless Signal Temperature Pressure Operating Hours 8 2 1 Software Version 01 Press CONFIRM to enter the So...

Page 40: ...IRM to enter the Wireless Signal menu 02 The next window will show the problems if the wireless connection had been lost or show the signal strength of your Wi Fi signal Problems wireless signal W DMX...

Page 41: ...nal strength 8 2 3 Temperature 01 Press CONFIRM to enter the Temperature menu 02 The next window will show you the current heater temperature 8 2 4 Pressure 01 Press CONFIRM to enter the Pressure menu...

Page 42: ...g Hours menu 02 The next window will show the total operating hours of your Mistique hazer 8 3 Setting 01 Press CONFIRM to enter the Information menu 02 Press the UP DOWN buttons to choose one of the...

Page 43: ...one of the 4 backlight modes Auto Off Low Normal High 04 Press CONFIRM to confirm your setting 8 3 2 Auto Start 01 Press CONFIRM to enter the Auto Start menu 02 Press UP DOWN to select one of the 2 mo...

Page 44: ...3 Ordercode 60769 Mistique 8 3 3 Factory Reset 01 Press CONFIRM to enter the Factory Reset menu 02 The next window will show 03 Press CONFIRM to confirm your setting 04 The device will now reset itsel...

Page 45: ...44 Ordercode 60769 Mistique 8 3 4 Language 01 Press CONFIRM to enter the Language menu 02 Press UP DOWN to select one of the 2 language modes EN ZH 03 Press CONFIRM to confirm your setting...

Page 46: ...tware Update 01 It is not possible to update the Mistique without contacting your dealer 02 Press CONFIRM to enter the Software Update menu 03 The next window will show 04 Press CONFIRM to go to the n...

Page 47: ...newer software version exists 08 If so send the device back to your dealer to have it updated 09 Press CONFIRM to confirm your setting 8 3 6 Keypad Sound 01 Press CONFIRM to enter the Keypad Sound me...

Page 48: ...Fan Speed 0 4 Off 5 255 5 40 psi Channel 3 Heating 0 127 Off 128 255 On 5 channels Channel 1 Output volume 0 4 Off 5 255 5 40 psi Channel 2 Fan Speed 0 4 Off 5 255 5 40 psi Channel 3 Heating 0 127 Of...

Page 49: ...Note Haze machines may sputter small amounts of haze occasionally during operation and for a about a minute after being turned off The device will use the automatically start the auto clean function...

Page 50: ...have to replace the fuse on this device as the fuse T8A 250 V is automatic 01 Unplug the unit from electric power source 02 In case of a power surge short circuit or inappropriate power supply press t...

Page 51: ...f the Mistique does not operate properly refer servicing to a technician 01 If you experience low output or no output at all unplug immediately 02 Check liquid level and power from the wall 03 If all...

Page 52: ...ft min Warm up time 6 min Automatic fuse 8A 250V Dimensions 503 x 334 x 310 mm LxWxH Weight 17 kg Electro mechanical effects Mounting Mounting bracket Housing Metal Flame retardant plastic Power conne...