background image

 

10 

Dipswitch setting for DMX Mode

 

When all dipswitches are turned off, the DJ LED Flower is in DMX Mode. 
- Dipswitches #1 - #8 control the DMX Addresses. 

 

 
 
 
 
 

      DMX Address 

 
DMX products must have their own "address" to receive DMX signals. 

Addresses on the controller are set 

by flipping the appropriate DMX dipswitches. 
 
You need to know that DMX address settings are the sum of the dip switch values. 
A standard DMX address for a Showtec LED Roto Flower, which has 6 channels is as follow: 
 

Example 

 

LED Roto Flower 

Address Value  

DMX Dip Switches "ON" 

Unit 5    

    

          25 

 

 

 

#1 , #4, #5 

 
Switch   

 

    Value 

    #1   

     

            1 

    #4   

                         8 

    #5   

                       16  + 

Total sum 

                       25 

 
Explanation: Since each unit has 6 channels, each address advances 6 values (See Address Value 
above). 

Once address values are determined, add DMX dipswitch values to obtain the appropriate address 
(DMX Dip Switches "ON") for each unit. Flip appropriate DMX dipswitches on each unit. 

 
Example: 
1.

 If you want to give an LED Roto Flower DMX address133, you first have to find the number 133 in the  

    DMX Chart. (See page 11) 

2.

 Then look at the left side (Dip Switches #1-#5) horizontally from 133. 

    In the Table you’ll see #1=ON, #2=OFF, #3=ON, #4=OFF, #5=OFF. 

3.

 Finally look at the upper side of the table (Dip Switches #6-#9) vertically from 133. 

    In the Table you’ll see #6=OFF, #7=OFF, #8=ON, #9=OFF. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for LED Roto Flower

Page 1: ...LED Roto Flower ORDERCODE 43032...

Page 2: ...on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Page 3: ...turn Procedure Claims Description Features and Overview Backside Installation Set Up and Operation Control Modes Built in Programs 1 7 All LEDs ON Automatic Sound Control Mode Master Slave Mode DMX Mo...

Page 4: ...000 hours will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may incl...

Page 5: ...ble voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces ca...

Page 6: ...on yourself Always let the installation be carried out by an authorized dealer Procedure If the LED Roto Flower is lowered from the ceiling or high joists professional trussing systems have to be used...

Page 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Page 8: ...ue 36 Beam angle 15 6 DMX channels Addressing by dipswitches Operation mode DMX512 Master Slave Sound controlled Built in Programs music controlled via built in microphone Fuse F2A 250V Overview 1 Fig...

Page 9: ...rom electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Control Modes There are 4 Modes 1 Built in Programs 1 7 All LEDs ON Automatic...

Page 10: ...rol 1 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 2 Use a 3 p XLR cable to connect the DJ LED Flower The pins 1 Earth 2 Signal 3 Signal 3 Link...

Page 11: ...DMX dip switches as follows See Dip Switch setting page 10 On the Master device Dipswitch 9 must be set to ON On all slave devices Dipswitch 9 must be set to OFF LED Roto Flower Address Value DMX Dip...

Page 12: ...tches ON Unit 5 25 1 4 5 Switch Value 1 1 4 8 5 16 Total sum 25 Explanation Since each unit has 6 channels each address advances 6 values See Address Value above Once address values are determined add...

Page 13: ...11...

Page 14: ...re s light output will be significantly reduced Disconnect the mains power supply and then wipe the cover with a damp cloth Do not immerse in liquid Wipe lens clean with glass cleaner and a soft cloth...

Page 15: ...s If not take the controller in for repair If so take the DMX cable and the light effect to a qualified technician Problem Probable cause s Remedy One or more fixtures are completely dead No power to...

Page 16: ...ration mode DMX512 master slave Sound controlled auto trigger music controlled via built in microphone Fuse F26A 250V Dimensions 315 x 238 x 216 mm Weight 3 6 kg Minimum distance Minimum distance from...

Page 17: ......

Reviews: