12
DMX Channels
Channel 1 – Built/in Programs
0-109
RGB Control
110-119
Program 1
120-129
Program 2
130-139
Program 3
140-149
Program 4
150-159
Program 5
160-169
Program 6
170-179
Program 7
180-199
Auto Running Mode
200-255
Sound Control Mode
Note
: When CH1 is set to 110-199, CH5 controls the speed of the programs
Channel 2 – Red
0-255
Gradual adjustment Red from 0 – 100%
Note
: For CH2 to function properly, CH1 has to be set to 0-109 and CH6 has to be used too.
Channel 3 – Green
0-255
Gradual adjustment Green from 0 – 100%
Note
: For CH3 to function properly, CH1 has to be set to 0-109 and CH6 has to be used too.
Channel 4 – Blue
0-255
Gradual adjustment Blue from 0 – 100%
Note
: For CH4 to function properly, CH1 has to be set to 0-109 and CH6 has to be used too.
Channel 5 – Strobe
0-255
Flashes from fast to slow
Channel 6 – Dimmer intensity
0-255
From black to brightest
Maintenance
The Showtec LED Roto Flower requires almost no maintenance. However, you should keep the unit clean.
Otherwise, the fixture’s light-output will be significantly reduced.
Disconnect the mains power supply, and
then wipe the cover with a damp cloth. Do not immerse in liquid. Wipe lens clean with glass cleaner and
a soft cloth. Do not use alcohol or solvents. Keep connections clean. Disconnect electric power, and
then wipe the connections with a damp cloth. Make sure connections are thoroughly dry before linking
equipment or supplying electric power.
The operator has to make sure that safety-relating and machine-technical installations are to be
inspected by an expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are to be
inspected by a skilled person once a year.
The following points have to be considered during the inspection:
1.
All screws used for installing the device or parts of the device have to be tightly connected and must
not be corroded.
2.
There may not be any deformations on housings, fixations and installation spots.
3.
Mechanically moving parts like axles, eyes and others may not show any traces of wearing.
4.
The electric power supply cables must not show any damages or material fatigue.