background image

 

OPERATING DETERMINATIONS 

• This device is not designed for permanent operation. Consistent operation breaks will ensure that the  
  device will serve you for a long time without defects.

 

• The minimum distance between light-output and the illuminated surface must be more than 0,5 meters. 
• The maximum ambient temperature 

t

a

 = 45°C must never be exceeded. 

• The relative humidity must not exceed 50 % with an ambient temperature of 45° C. 
• If this device is operated in any other way, than the one described in this manual, the product may  
   suffer damages and the

 

warranty becomes void.  

• Any other operation may lead to dangers like short-circuit, burns, electric shock, crash etc. 
 
You endanger your own safety and the safety of others! 
 
 

Rigging 

 

Please follow the European and national guidelines concerning rigging, trussing and all other 
safety issues. 

 

Do not attempt the installation yourself ! 
Always let the installation be carried out by an authorized dealer !

 

 

Procedure: 

 

If the LED Roto Flower is lowered from the ceiling or high joists, professional trussing systems have to 
be used. 

 

Use a clamp to mount the LED Roto Flower, with the mounting-bracket, to the trussing system. 

 

The LED Roto Flower must never be fixed swinging freely in the room.  

 

The installation must always be secured with a safety attachment, e.g. an appropriate safety net 
or safety-cable. 

 

When rigging, derigging or servicing the device, always make sure, that the area below the 
installation place is blocked and staying in the area is forbidden. 

 

Improper installation can cause serious damage to people and property !

 

 

 

Connection with the mains

 

 

Connect the device to the mains with the power-plug. 
Always pay attention, that the right color cable is connected to the right place. 
 

 International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN 

RED 

YELLOW/COPPER 

FASE 

BLUE 

BLACK 

SILVER 

NUL 

 

YELLOW/GREEN 

GREEN 

GREEN 

EARTH 

 
Make sure that the device is always connected 

properly

 to the earth!  

 
 
 
 
 
 
 
 
 

Summary of Contents for LED Roto Flower

Page 1: ...LED Roto Flower ORDERCODE 43032...

Page 2: ...on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Page 3: ...turn Procedure Claims Description Features and Overview Backside Installation Set Up and Operation Control Modes Built in Programs 1 7 All LEDs ON Automatic Sound Control Mode Master Slave Mode DMX Mo...

Page 4: ...000 hours will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may incl...

Page 5: ...ble voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces ca...

Page 6: ...on yourself Always let the installation be carried out by an authorized dealer Procedure If the LED Roto Flower is lowered from the ceiling or high joists professional trussing systems have to be used...

Page 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Page 8: ...ue 36 Beam angle 15 6 DMX channels Addressing by dipswitches Operation mode DMX512 Master Slave Sound controlled Built in Programs music controlled via built in microphone Fuse F2A 250V Overview 1 Fig...

Page 9: ...rom electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Control Modes There are 4 Modes 1 Built in Programs 1 7 All LEDs ON Automatic...

Page 10: ...rol 1 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 2 Use a 3 p XLR cable to connect the DJ LED Flower The pins 1 Earth 2 Signal 3 Signal 3 Link...

Page 11: ...DMX dip switches as follows See Dip Switch setting page 10 On the Master device Dipswitch 9 must be set to ON On all slave devices Dipswitch 9 must be set to OFF LED Roto Flower Address Value DMX Dip...

Page 12: ...tches ON Unit 5 25 1 4 5 Switch Value 1 1 4 8 5 16 Total sum 25 Explanation Since each unit has 6 channels each address advances 6 values See Address Value above Once address values are determined add...

Page 13: ...11...

Page 14: ...re s light output will be significantly reduced Disconnect the mains power supply and then wipe the cover with a damp cloth Do not immerse in liquid Wipe lens clean with glass cleaner and a soft cloth...

Page 15: ...s If not take the controller in for repair If so take the DMX cable and the light effect to a qualified technician Problem Probable cause s Remedy One or more fixtures are completely dead No power to...

Page 16: ...ration mode DMX512 master slave Sound controlled auto trigger music controlled via built in microphone Fuse F26A 250V Dimensions 315 x 238 x 216 mm Weight 3 6 kg Minimum distance Minimum distance from...

Page 17: ......

Reviews: