background image

 

      

Return Procedure 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

1) Your name 
2) Your address 
3) Your phone number 
4) A brief description of the symptoms  
 
 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
 It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting.  
 

 

Summary of Contents for DB-1-8

Page 1: ...DB 1 8 ORDERCODE 50783 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Page 2: ...howtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our...

Page 3: ...terminations 4 Rigging 4 Return Procedure 5 Claims 5 Description of the device 6 Overview 6 Installation 7 Set Up and Operation 7 DMX Setup Example 7 Fixture Linking 9 Data Cabling 9 Maintenance 10 Re...

Page 4: ...will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climat...

Page 5: ...ot higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces can impact on the...

Page 6: ...he installation yourself Always let the installation be carried out by an authorized dealer Procedure If the DB 1 8 is lowered from the ceiling or high joists professional trussing systems have to be...

Page 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Page 8: ...tter Additional thru output 3 pin and 5 pin for linking to other Data Streams Electrical isolation between input and output 19 inch device 1U 1HE rack mount AC power Auto switching 100V 240V 50 60Hz D...

Page 9: ...fixtures set to a master slave operating mode The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support DMX Setup E...

Page 10: ...no data received at the DMX input the problem may be The XLR cable from the controller is not connected with the input of the first fixture The controller is switched off or defective the cable or con...

Page 11: ...may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of movingheads on a single DMX data link 32 fixtures Data Cabling...

Page 12: ...nsert a flat head screwdriver into a slot in the fuse cover Turn the screwdriver to the left at the same time gently push a bit Turn and Push The fuse will come out 3 Remove the used fuse If brown or...

Page 13: ...d connect them directly together Have the defective fixture serviced by a qualified technician Lamps cuts off sporadically Possible bad lamp or the fixture is overheating Lamp may be at the end of its...

Page 14: ...10 nut on the rear end of the unit It has clear LEDs to show the DMX signal status of each output and input Universal DMX 512 optical splitter Additional thru output 3 pin and 5 pin for linking to oth...

Page 15: ......

Reviews: