Maintenance

 

The Showtec DB-1-8 requires almost no maintenance. However, you should keep the unit clean. 

Otherwise, the fixture’s light-output will be significantly reduced. 

Disconnect the mains power supply, and 

then wipe the cover with a damp cloth. Do not immerse in liquid. Wipe lens clean with glass cleaner and 
a soft cloth. Do not use alcohol or solvents. Keep connections clean. Disconnect electric power, and 
then wipe the connections with a damp cloth. Make sure connections are thoroughly dry before linking 
equipment or supplying electric power. 

 

The operator has to make sure that safety-relating and machine-technical installations are to be 
inspected by an expert after every four years in the course of an acceptance test. 
The operator has to make sure that safety-relating and machine-technical installations are to be 
inspected by a skilled person once a year. 
 
The following points have to be considered during the inspection: 

1.

 

All screws used for installing the device or parts of the device have to be tightly connected and must 
not be corroded. 

2.

 

There may not be any deformations on housings, fixations and installation spots. 

3.

 

Mechanically moving parts like axles, eyes and others may not show any traces of wearing. 

4.

 

The electric power supply cables must not show any damages or material fatigue. 

 

Replacing a Fuse 

Power surges, short-circuit or inappropriate electrical power supply may cause a fuse to burn out. If the 
fuse burns out, the product will not function whatsoever. If this happens, 

follow the directions below to do 

so.

 

1.

 

Unplug the unit from electric power source

2.

 

Insert a flat-head screwdriver into a slot in the fuse cover. Turn the screwdriver to the left, at the same 
time gently push a bit (Turn and Push)

. The fuse will come out.

 

3.

 

Remove the used fuse. If brown or unclear, it is burned out

4.

 

Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse cover. Be sure to 

use a fuse of the same type and specification. See the product specification label for details. 

 
 

Troubleshooting 

This troubleshooting guide is meant to help solve simple problems.  
If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit 
operates properly, do not carry out following steps. 
If the light effect does not operate properly, refer servicing to a technician. 
Response: Suspect two potential problem areas: the power supply, the fuse. 

1.

 

Power supply. Check that the unit is plugged into an appropriate power supply. 

2.

 

The fuse. Replace the fuse. See page 10 for replacing the fuse. 

3.

 

If all of the above appears to be O.K., plug the unit in again. 

4.

 

If you are unable to determine the cause of the problem, do not open the 

DB-1-8

, as this may 

damage the unit and the warranty will become void. 

5.

 

Return the device to your Showtec dealer. 

 
 

No Response to DMX 

Response: Suspect the DMX cable or connectors, a controller malfunction, a light effect DMX card 
malfunction. 

1.

 

Check the DMX setting. Make sure that DMX addresses are correct. 

2.

 

Check the DMX cable: Unplug the unit; change the DMX cable; then reconnect to electrical power. 
Try your DMX control again. 

3.

 

Determine whether the controller or light effect is at fault. Does the controller operate properly with 
other DMX products ? If not, take the controller in for repair. If so, take the DMX cable and the light 
effect to a qualified technician. 

 
See next page for more problem solving. 

 

Summary of Contents for DB-1-8

Page 1: ...DB 1 8 ORDERCODE 50783 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Page 2: ...howtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our...

Page 3: ...terminations 4 Rigging 4 Return Procedure 5 Claims 5 Description of the device 6 Overview 6 Installation 7 Set Up and Operation 7 DMX Setup Example 7 Fixture Linking 9 Data Cabling 9 Maintenance 10 Re...

Page 4: ...will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climat...

Page 5: ...ot higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces can impact on the...

Page 6: ...he installation yourself Always let the installation be carried out by an authorized dealer Procedure If the DB 1 8 is lowered from the ceiling or high joists professional trussing systems have to be...

Page 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Page 8: ...tter Additional thru output 3 pin and 5 pin for linking to other Data Streams Electrical isolation between input and output 19 inch device 1U 1HE rack mount AC power Auto switching 100V 240V 50 60Hz D...

Page 9: ...fixtures set to a master slave operating mode The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support DMX Setup E...

Page 10: ...no data received at the DMX input the problem may be The XLR cable from the controller is not connected with the input of the first fixture The controller is switched off or defective the cable or con...

Page 11: ...may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of movingheads on a single DMX data link 32 fixtures Data Cabling...

Page 12: ...nsert a flat head screwdriver into a slot in the fuse cover Turn the screwdriver to the left at the same time gently push a bit Turn and Push The fuse will come out 3 Remove the used fuse If brown or...

Page 13: ...d connect them directly together Have the defective fixture serviced by a qualified technician Lamps cuts off sporadically Possible bad lamp or the fixture is overheating Lamp may be at the end of its...

Page 14: ...10 nut on the rear end of the unit It has clear LEDs to show the DMX signal status of each output and input Universal DMX 512 optical splitter Additional thru output 3 pin and 5 pin for linking to oth...

Page 15: ......

Reviews: