background image

 

Fixture Linking 

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to 
run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined 
number of channels required by all the fixtures on a serial data link determines the number of fixtures the 
data link can support.  

 
 

Important:

  

Fixtures on a serial data link must be daisy chained in one single line. To comply with the  
EIA-485 standard no more than 30 devices should be connected on one data link. 
Connecting more than 30 fixtures on one serial data link without the use of a DMX optically 
isolated splitter may result in deterioration of the digital DMX signal. 
 
Maximum recommended DMX data link distance: 100 meters 
Maximum recommended number of movingheads on a single DMX data link: 32 fixtures 
 

 

Data Cabling 

To link fixtures together you must obtain data cables. You can purchase DAP Audio certified DMX cables 
directly from a dealer/distributor or construct your own cable. If you choose to create your own cable 
please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic 
interference. 
 

DAP Audio Certified DMX Data Cables 

 

DAP Audio cable for allround use. 

bal. XLR/M 3 p. > XLR/F 3 p.  

Ordercode

 FL01150 (1,5m.), FL013 (3m.), FL016 (6m.), FL0110 (10m.), FL0115 (15m.), FL0120 (20m.). 

 

DAP Audio cable f

or the demanding user with exceptional audio-qualities and connector made by 

Neutrik®.

 Ordercode

 FL71150 (1,5m.), FL713 (3m.), FL716 (6m.), FL7110 (10m.). 

 
 
 
 
 
 
 
 
 
 
 
 

 

Summary of Contents for DB-1-8

Page 1: ...DB 1 8 ORDERCODE 50783 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Page 2: ...howtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our...

Page 3: ...terminations 4 Rigging 4 Return Procedure 5 Claims 5 Description of the device 6 Overview 6 Installation 7 Set Up and Operation 7 DMX Setup Example 7 Fixture Linking 9 Data Cabling 9 Maintenance 10 Re...

Page 4: ...will be achieved under normal operational conditions If improving on this lifespan expectancy is of a higher priority place care in providing for lower operational temperatures This may include climat...

Page 5: ...ot higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time Make sure that no side forces can impact on the...

Page 6: ...he installation yourself Always let the installation be carried out by an authorized dealer Procedure If the DB 1 8 is lowered from the ceiling or high joists professional trussing systems have to be...

Page 7: ...description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our ann...

Page 8: ...tter Additional thru output 3 pin and 5 pin for linking to other Data Streams Electrical isolation between input and output 19 inch device 1U 1HE rack mount AC power Auto switching 100V 240V 50 60Hz D...

Page 9: ...fixtures set to a master slave operating mode The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support DMX Setup E...

Page 10: ...no data received at the DMX input the problem may be The XLR cable from the controller is not connected with the input of the first fixture The controller is switched off or defective the cable or con...

Page 11: ...may result in deterioration of the digital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of movingheads on a single DMX data link 32 fixtures Data Cabling...

Page 12: ...nsert a flat head screwdriver into a slot in the fuse cover Turn the screwdriver to the left at the same time gently push a bit Turn and Push The fuse will come out 3 Remove the used fuse If brown or...

Page 13: ...d connect them directly together Have the defective fixture serviced by a qualified technician Lamps cuts off sporadically Possible bad lamp or the fixture is overheating Lamp may be at the end of its...

Page 14: ...10 nut on the rear end of the unit It has clear LEDs to show the DMX signal status of each output and input Universal DMX 512 optical splitter Additional thru output 3 pin and 5 pin for linking to oth...

Page 15: ......

Reviews: