SHOWTEC Aircone Q6 WDMX Manual Download Page 4

 

  

 

 

   

 

Ordercode: 40314 

Aircone Q6 WDMX 

Before the initial start-up, please make sure that there is no damage caused by transportation.  
Should there be any, consult your dealer and do not use the device. 
 
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 
follow the safety instructions and warning notes contained in this manual. 
 
Please consider that damages caused by manual modifications to the device are not subject to 
warranty. 
 
This device contains no user-serviceable parts. Refer servicing to qualified technicians only. 
 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the device. 
 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never lift the fixture holding it by the projector-head, as the mechanics may be damaged. Always 
hold the fixture by the transport handles. 

 

Never place any material over the lens. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmer pack. 

 

Do not switch the device on and off in short intervals, as this will reduce the device’s life. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use the device indoors, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked if the housing is firmly closed and all screws are tightly 
fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep the case closed while operating. 

 

Always allow a free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 
the power cord holding it by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 
cord from time to time. 

 

If device was dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue the use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. The device must be installed beyond the reach of children. Never leave the unit 
running unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

For replacement use fuses of same type and rating only. 

 

The user is responsible for correct positioning and operating of the Aircone. The manufacturer will not 
accept liability for damages caused by the misuse or incorrect installation of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

 

Summary of Contents for Aircone Q6 WDMX

Page 1: ...Aircone Q6 WDMX V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 40314 MANUAL ENGLISH...

Page 2: ...ircone Sound controlled 10 Multiple Aircones Master Slave control 10 Multiple Aircones DMX Control 11 Fixture Linking 12 Data Cabling 12 Control Panel 13 Control Mode 13 DMX Addressing 13 Menu Overvie...

Page 3: ...1 x cone with Velcro PowerCON power cable 1 5 m 2 x quick lock brackets for truss mounting User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor...

Page 4: ...miliarized with its functions Avoid flames and do not put close to flammable liquids or gases Always keep the case closed while operating Always allow a free air space of at least 50 cm around the uni...

Page 5: ...es void Any other operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national...

Page 6: ...e mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER...

Page 7: ...mber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this che...

Page 8: ...ors Sound Slave DMX Control protocol DMX 512 WDMX Dimmer 0 100 Strobe 0 20Hz Connections 3 pin XLR data connectors IN OUT PowerCON power connector IN OUT IP rating IP 20 Housing Aluminum Color Black C...

Page 9: ...r servicing Damages caused by non observance are not subject to warranty Set Up and Operation Follow the directions below as they pertain to your preferred operation mode Before plugging the unit in a...

Page 10: ...lable wireless DMX receivers The LED indicator 09 will be blinking fast Once the connection has been established the LED indicator 09 remains on 02 Press one of the control buttons 06 to enter main me...

Page 11: ...a proper electric power supply socket 03 Turn on the music If the device is set to sound control then the Aircone will react to the beat of the music Please see page 16 for more information about the...

Page 12: ...t the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth units 05 Supply electric power Plug electric mains p...

Page 13: ...on a power link 230V 7 fixtures Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your...

Page 14: ...of the third Aircone should be 13 12 25 025 etc Please be sure that you do not have any overlapping channels in order to control each Aircone correctly If two or more Aircones are addressed similarly...

Page 15: ...14 Ordercode 40314 Aircone Q6 WDMX Menu Overview...

Page 16: ...e adjustment range is between and 04 If you have chosen press the SETUP button to open the menu 05 Press the UP DOWN buttons to choose the desired color macro The adjustment range is between 06 Press...

Page 17: ...on until the display shows 02 Press the SETUP button to enter 03 Press the UP DOWN buttons to set the sound sensitivity The adjustment range is between from OFF to high sound sensitivity 5 DMX 512 01...

Page 18: ...e UP DOWN buttons to choose OFF or HOLD 02 If you have chosen in case of a DMX failure the Aircone will cut off its light output 03 If you have chosen in case of a DMX failure the Aircone will use the...

Page 19: ...G 255 B 255 W 150 A 0 P 255 112 118 Color 16 R 0 G 100 B 255 W 255 A 0 P 255 119 125 Color 17 R 0 G 0 B 255 W 100 A 0 P 255 126 132 Color 18 R 0 G 0 B 255 W 50 A 0 P 255 133 139 Color 19 R 0 G 0 B 255...

Page 20: ...153 Color 21 R 160 G 0 B 255 W 0 A 0 P 255 154 160 Color 22 R 255 G 0 B 255 W 0 A 0 P 255 161 167 Color 23 R 255 G 0 B 175 W 0 A 0 P 175 168 174 Color 24 R 255 G 0 B 100 W 0 A 0 P 100 175 181 Color 25...

Page 21: ...41 Color 5 R 255 G 255 B 0 W 0 A 120 P 0 42 48 Color 6 R 255 G 255 B 0 W 75 A 0 P 0 49 55 Color 7 R 0 G 255 B 0 W 255 A 0 P 0 56 62 Color 8 R 0 G 255 B 0 W 150 A 0 P 0 63 69 Color 9 R 0 G 255 B 0 W 50...

Page 22: ...speed adjustment from slow to fast Channel 5 Sound sensitivity CH4 must be set between 252 255 0 255 Sound sensitivity from low to high sensitivity Channel 6 Fan speed 0 255 Fan speed adjustment from...

Page 23: ...p cloth Do not immerse in liquid Wipe lens clean with glass cleaner and a soft cloth Do not use alcohol or solvents The front lens will require weekly cleaning as smoke fluid tends to build up residue...

Page 24: ...or replacing the fuse 04 If all appears to be O K plug the unit in again 05 If you are unable to determine the cause of the problem do not open the Aircone as this may damage the unit and the warranty...

Page 25: ...ect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture o...

Page 26: ...LEDs Cone length 2500 mm Dimmer 0 100 Strobe 0 20Hz Housing Aluminum DMX control via standard DMX controller Onboard 4 digit LED display for easy setup Control Auto Built in programs Static Colors Sou...

Page 27: ...26 Ordercode 40314 Aircone Q6 WDMX Dimensions...

Page 28: ...2017 Showtec...

Reviews: