Fixture Linking 

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to 
run synchronized shows of two or more fixtures set to a master/slave operating mode. The combined 
number of channels required by all the fixtures on a serial data link determines the number of fixtures the 
data link can support. 
 
Important:  Fixtures on a serial data link must be daisy-chained in a single line. To comply with the  

EIA-485 standard, no more than 30 devices should be connected on one data link. 
Connecting more than 30 fixtures on one serial data link without the use of a DMX optically 
isolated splitter may result in deterioration of the digital DMX signal. 

 

Maximum recommended DMX data link distance: 100 meters 
Maximum recommended number of fixtures on a DMX data link: 30 fixtures 
Maximum recommended number of devices on a power link @120V: 3 fixtures 
Maximum recommended number of devices on a power link @230V: 7 fixtures 

 

Data Cabling 

To link fixtures together, you must obtain data cables. You can purchase DAP Audio certified DMX cables 
directly from a dealer/distributor or construct your own cable. If you choose to create your own cable, 
please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic 
interference. 
 
DAP Audio DMX Data Cables 

 

DAP Audio Basic microphone cable for allround use. bal. XLR/M 3-pin > XLR/F 3-pin.  
Ordercode FL01150 (1,5 m), FL013 (3 m), FL016 (6 m), FL0110 (10 m), FL0115 (15 m), FL0120 (20 m). 

 

DAP Audio X-type data cable XLR/M 3-pin > XLR/F 3-pin. Ordercode FLX0175 (0,75 m), 
FLX01150 (1,5 m), FLX013 (3 m), FLX016 (6 m), FLX0110 (10 m).

 

 

DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by 
Neutrik®. Ordercode FL71150 (1,5 m), FL713 (3 m), FL716 (6 m), FL7110 (10 m). 

 

DAP Audio cable for the demanding user with exceptional audio-qualities and connector made by 
Neutrik®. Ordercode FL7275 (0,75 m), FL72150 (1,5 m), FL723 (3 m), FL726 (6 m), FL7210 (10 m). 

 

DAP Audio 110 Ohm cable with digital signal transmission. Ordercode FL0975 (0,75 m), 
FL09150 (1,5 m), FL093 (3 m), FL096 (6 m), FL0910 (10 m), FL0915 (15 m), FL0920 (20 m). 

 

 

Summary of Contents for Aircone Q6 WDMX

Page 1: ...Aircone Q6 WDMX V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 40314 MANUAL ENGLISH...

Page 2: ...ircone Sound controlled 10 Multiple Aircones Master Slave control 10 Multiple Aircones DMX Control 11 Fixture Linking 12 Data Cabling 12 Control Panel 13 Control Mode 13 DMX Addressing 13 Menu Overvie...

Page 3: ...1 x cone with Velcro PowerCON power cable 1 5 m 2 x quick lock brackets for truss mounting User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor...

Page 4: ...miliarized with its functions Avoid flames and do not put close to flammable liquids or gases Always keep the case closed while operating Always allow a free air space of at least 50 cm around the uni...

Page 5: ...es void Any other operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national...

Page 6: ...e mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER...

Page 7: ...mber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this che...

Page 8: ...ors Sound Slave DMX Control protocol DMX 512 WDMX Dimmer 0 100 Strobe 0 20Hz Connections 3 pin XLR data connectors IN OUT PowerCON power connector IN OUT IP rating IP 20 Housing Aluminum Color Black C...

Page 9: ...r servicing Damages caused by non observance are not subject to warranty Set Up and Operation Follow the directions below as they pertain to your preferred operation mode Before plugging the unit in a...

Page 10: ...lable wireless DMX receivers The LED indicator 09 will be blinking fast Once the connection has been established the LED indicator 09 remains on 02 Press one of the control buttons 06 to enter main me...

Page 11: ...a proper electric power supply socket 03 Turn on the music If the device is set to sound control then the Aircone will react to the beat of the music Please see page 16 for more information about the...

Page 12: ...t the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth units 05 Supply electric power Plug electric mains p...

Page 13: ...on a power link 230V 7 fixtures Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your...

Page 14: ...of the third Aircone should be 13 12 25 025 etc Please be sure that you do not have any overlapping channels in order to control each Aircone correctly If two or more Aircones are addressed similarly...

Page 15: ...14 Ordercode 40314 Aircone Q6 WDMX Menu Overview...

Page 16: ...e adjustment range is between and 04 If you have chosen press the SETUP button to open the menu 05 Press the UP DOWN buttons to choose the desired color macro The adjustment range is between 06 Press...

Page 17: ...on until the display shows 02 Press the SETUP button to enter 03 Press the UP DOWN buttons to set the sound sensitivity The adjustment range is between from OFF to high sound sensitivity 5 DMX 512 01...

Page 18: ...e UP DOWN buttons to choose OFF or HOLD 02 If you have chosen in case of a DMX failure the Aircone will cut off its light output 03 If you have chosen in case of a DMX failure the Aircone will use the...

Page 19: ...G 255 B 255 W 150 A 0 P 255 112 118 Color 16 R 0 G 100 B 255 W 255 A 0 P 255 119 125 Color 17 R 0 G 0 B 255 W 100 A 0 P 255 126 132 Color 18 R 0 G 0 B 255 W 50 A 0 P 255 133 139 Color 19 R 0 G 0 B 255...

Page 20: ...153 Color 21 R 160 G 0 B 255 W 0 A 0 P 255 154 160 Color 22 R 255 G 0 B 255 W 0 A 0 P 255 161 167 Color 23 R 255 G 0 B 175 W 0 A 0 P 175 168 174 Color 24 R 255 G 0 B 100 W 0 A 0 P 100 175 181 Color 25...

Page 21: ...41 Color 5 R 255 G 255 B 0 W 0 A 120 P 0 42 48 Color 6 R 255 G 255 B 0 W 75 A 0 P 0 49 55 Color 7 R 0 G 255 B 0 W 255 A 0 P 0 56 62 Color 8 R 0 G 255 B 0 W 150 A 0 P 0 63 69 Color 9 R 0 G 255 B 0 W 50...

Page 22: ...speed adjustment from slow to fast Channel 5 Sound sensitivity CH4 must be set between 252 255 0 255 Sound sensitivity from low to high sensitivity Channel 6 Fan speed 0 255 Fan speed adjustment from...

Page 23: ...p cloth Do not immerse in liquid Wipe lens clean with glass cleaner and a soft cloth Do not use alcohol or solvents The front lens will require weekly cleaning as smoke fluid tends to build up residue...

Page 24: ...or replacing the fuse 04 If all appears to be O K plug the unit in again 05 If you are unable to determine the cause of the problem do not open the Aircone as this may damage the unit and the warranty...

Page 25: ...ect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture o...

Page 26: ...LEDs Cone length 2500 mm Dimmer 0 100 Strobe 0 20Hz Housing Aluminum DMX control via standard DMX controller Onboard 4 digit LED display for easy setup Control Auto Built in programs Static Colors Sou...

Page 27: ...26 Ordercode 40314 Aircone Q6 WDMX Dimensions...

Page 28: ...2017 Showtec...

Reviews: