SHOWTEC Aircone Q6 WDMX Manual Download Page 14

 

  

 

 

13 

   

 

Ordercode: 40314 

Aircone Q6 WDMX 

The Aircone Q6 WDMX can be operated with a controller in control mode or without the controller in  
stand-alone mode. 
 

Control Panel 

 

 

A)  LED display 
B)  MODE button 
C)  SETUP button 
D)  UP button 
E)   DOWN button 

 
 

Fig. 05 

 

 

 

Control Mode 

The fixtures are individually addressed on a data-link and connected to the controller.  
The fixtures respond to the DMX signal from the controller. (When you select the DMX address and save it, 
the controller will display the saved DMX address, next time.) 
 

DMX Addressing 

The control panel on the front side of the base allows you to assign DMX fixture addresses, which is the first 
channel with which the Aircone will respond to the controller. 
Please note, when you use the controller, the unit has 12 channels. 
When using multiple Aircones, make sure you set the DMX addresses right. 
Therefore, the DMX address of the first Aircone should be 1(001); the DMX address of the second Aircone 
should be 1+12=13 (013); the DMX address of the third Aircone should be 13+12=25 (025), etc. 
Please, be sure that you do not have any overlapping channels in order to control each Aircone 
correctly. If two or more Aircones are addressed similarly, they will work similarly. 
 

Controlling: 

After having addressed all Aircone fixtures, you may now start operating these via your lighting controller. 
Note:
 After switching on, the Aircone will automatically detect whether DMX 512 data is received or not.  
If there is no data received at the DMX-input, the “LED “ on the control panel will not flash. 
If not, the problem may be: 

 

The XLR cable from the controller is not connected with the input of the Aircone Q6 WDMX. 

 

The controller is switched off or defective, the cable or connector is detective, or the signal wires are 
swapped in the input connector. 

 
Note: It is necessary to insert an XLR termination plug (with 120 Ohm) in the last fixture in order to ensure 
proper transmission on the DMX data link.  
 

 

Display Off after 60 seconds

 

 

When no button is pressed for 60 seconds, the display will turn off. 
To light up the display, you have to press the MODE, SETUP, UP or DOWN button. 
Once you have pressed the button, the display will light up. 
 
 

 

Summary of Contents for Aircone Q6 WDMX

Page 1: ...Aircone Q6 WDMX V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 40314 MANUAL ENGLISH...

Page 2: ...ircone Sound controlled 10 Multiple Aircones Master Slave control 10 Multiple Aircones DMX Control 11 Fixture Linking 12 Data Cabling 12 Control Panel 13 Control Mode 13 DMX Addressing 13 Menu Overvie...

Page 3: ...1 x cone with Velcro PowerCON power cable 1 5 m 2 x quick lock brackets for truss mounting User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor...

Page 4: ...miliarized with its functions Avoid flames and do not put close to flammable liquids or gases Always keep the case closed while operating Always allow a free air space of at least 50 cm around the uni...

Page 5: ...es void Any other operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national...

Page 6: ...e mains Connect the device to the mains with the power plug Always check if the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER...

Page 7: ...mber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this che...

Page 8: ...ors Sound Slave DMX Control protocol DMX 512 WDMX Dimmer 0 100 Strobe 0 20Hz Connections 3 pin XLR data connectors IN OUT PowerCON power connector IN OUT IP rating IP 20 Housing Aluminum Color Black C...

Page 9: ...r servicing Damages caused by non observance are not subject to warranty Set Up and Operation Follow the directions below as they pertain to your preferred operation mode Before plugging the unit in a...

Page 10: ...lable wireless DMX receivers The LED indicator 09 will be blinking fast Once the connection has been established the LED indicator 09 remains on 02 Press one of the control buttons 06 to enter main me...

Page 11: ...a proper electric power supply socket 03 Turn on the music If the device is set to sound control then the Aircone will react to the beat of the music Please see page 16 for more information about the...

Page 12: ...t the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth units 05 Supply electric power Plug electric mains p...

Page 13: ...on a power link 230V 7 fixtures Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your...

Page 14: ...of the third Aircone should be 13 12 25 025 etc Please be sure that you do not have any overlapping channels in order to control each Aircone correctly If two or more Aircones are addressed similarly...

Page 15: ...14 Ordercode 40314 Aircone Q6 WDMX Menu Overview...

Page 16: ...e adjustment range is between and 04 If you have chosen press the SETUP button to open the menu 05 Press the UP DOWN buttons to choose the desired color macro The adjustment range is between 06 Press...

Page 17: ...on until the display shows 02 Press the SETUP button to enter 03 Press the UP DOWN buttons to set the sound sensitivity The adjustment range is between from OFF to high sound sensitivity 5 DMX 512 01...

Page 18: ...e UP DOWN buttons to choose OFF or HOLD 02 If you have chosen in case of a DMX failure the Aircone will cut off its light output 03 If you have chosen in case of a DMX failure the Aircone will use the...

Page 19: ...G 255 B 255 W 150 A 0 P 255 112 118 Color 16 R 0 G 100 B 255 W 255 A 0 P 255 119 125 Color 17 R 0 G 0 B 255 W 100 A 0 P 255 126 132 Color 18 R 0 G 0 B 255 W 50 A 0 P 255 133 139 Color 19 R 0 G 0 B 255...

Page 20: ...153 Color 21 R 160 G 0 B 255 W 0 A 0 P 255 154 160 Color 22 R 255 G 0 B 255 W 0 A 0 P 255 161 167 Color 23 R 255 G 0 B 175 W 0 A 0 P 175 168 174 Color 24 R 255 G 0 B 100 W 0 A 0 P 100 175 181 Color 25...

Page 21: ...41 Color 5 R 255 G 255 B 0 W 0 A 120 P 0 42 48 Color 6 R 255 G 255 B 0 W 75 A 0 P 0 49 55 Color 7 R 0 G 255 B 0 W 255 A 0 P 0 56 62 Color 8 R 0 G 255 B 0 W 150 A 0 P 0 63 69 Color 9 R 0 G 255 B 0 W 50...

Page 22: ...speed adjustment from slow to fast Channel 5 Sound sensitivity CH4 must be set between 252 255 0 255 Sound sensitivity from low to high sensitivity Channel 6 Fan speed 0 255 Fan speed adjustment from...

Page 23: ...p cloth Do not immerse in liquid Wipe lens clean with glass cleaner and a soft cloth Do not use alcohol or solvents The front lens will require weekly cleaning as smoke fluid tends to build up residue...

Page 24: ...or replacing the fuse 04 If all appears to be O K plug the unit in again 05 If you are unable to determine the cause of the problem do not open the Aircone as this may damage the unit and the warranty...

Page 25: ...ect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture o...

Page 26: ...LEDs Cone length 2500 mm Dimmer 0 100 Strobe 0 20Hz Housing Aluminum DMX control via standard DMX controller Onboard 4 digit LED display for easy setup Control Auto Built in programs Static Colors Sou...

Page 27: ...26 Ordercode 40314 Aircone Q6 WDMX Dimensions...

Page 28: ...2017 Showtec...

Reviews: