background image

 

  

 

 

   

 

Order code: 34011 

ACT Fresnel 50 WW 

Rigging 
Please follow the European and national guidelines concerning rigging, trussing and all 
other safety issues. 

 

Do not attempt the installation yourself! 
Always let the installation be carried out by an authorized dealer! 

 

Procedure: 

 

If the device is lowered from the ceiling or high joists, professional trussing systems have to be used. 

 

Use a clamp to mount the device with the mounting bracket to the trussing system. 

 

The device must never be fixed swinging freely in the room. 

 

The installation must always be secured with a safety attachment, e.g. an appropriate safety net or 
safety cable. 

 

If the barndoor or the color filter is installed, it must be secured with a safety cable. 

 

When rigging, derigging or servicing the device, always make sure, that the area below the 
installation site is secured and that there are not any unauthorized people around. 

 

Improper installation can cause serious injuries and/or damage of property! 

 

 

 

 

Angle Adjustment 
You can adjust the angle of the device with the adjustment handle (06)
01)

 

Turn the adjustment handle (06) counterclockwise to release it. 

02)

 

Tilt the device at the desired angle (see Fig. 01). 

03)

 

Turn the adjustment handle (06) clockwise to tighten it. Make sure that the device cannot move 
freely after the adjustment handle (06) is tightened. 

 

Fig. 01 

Summary of Contents for ACT Fresnel 50 WW

Page 1: ...ACT Fresnel 50 WW V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Order code 34011 MANUAL ENGLISH...

Page 2: ...CT Fresnel Manual Control 11 Multiple ACT Fresnels DMX Control 12 Fixture Linking 13 Data Cabling 13 Control Panel 14 DMX Addressing 14 Main Menu Overview 15 Start up 16 Main Menu Options 16 1 DMX Fun...

Page 3: ...owtec ACT Fresnel 50 WW Barndoor Color frame Schuko to pro power cable 1 5 m User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to...

Page 4: ...ater or other liquids Only operate the fixture after having checked if the housing is firmly closed and all screws are tightly fastened Only operate the device after having familiarized with its funct...

Page 5: ...inimum distance between light output and the illuminated surface must be bigger than 1 m In order to eliminate wear and improve the device s lifespan during periods of non use completely disconnect fr...

Page 6: ...h a safety attachment e g an appropriate safety net or safety cable If the barndoor or the color filter is installed it must be secured with a safety cable When rigging derigging or servicing the devi...

Page 7: ...per UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your add...

Page 8: ...nt Output 10 3430 lx 2 m 58 402 lx 2 m Color temperature 3200 K Light quality CRI 98 Dimmer 0 100 Strobe effect Yes Zoom Manual Connections Pro power connectors IN OUT 3 pin DMX signal connectors IN O...

Page 9: ...ns 10 3 pin DMX signal connector OUT 11 Fuse T1 AL 250 V AC 12 Pro power connector OUT 100 240 V 7A 50 60 Hz Gray 13 Pro power connector IN 100 240 V 7A 50 60 Hz Blue 14 3 pin DMX signal connector IN...

Page 10: ...e power OUT connector Note that the input and the output connectors have different designs one type cannot be connected to the other To link fixtures in a chain a hard usage cable with appropriate cab...

Page 11: ...clip before using the ACT Fresnel 50 WW Color Frame Installation The ACT Fresnel 50 WW is delivered with a color frame You can insert a color gel or a diffusion filter into the color frame To install...

Page 12: ...the following 03 Turn the manual dimmer control 15 to adjust the intensity of the light The adjustment range is between 0 and 255 from 0 to 100 The current value of the dimmer is displayed on the scre...

Page 13: ...in socket using a DMX cable Connect the first unit s out socket with the second unit s in socket using a DMX cable Repeat this process to link the rest of the units 05 Supply electric power Plug elect...

Page 14: ...gnal Maximum recommended DMX data link distance 100 meters Maximum recommended number of fixtures on a DMX data link 30 fixtures Data Cabling To link fixtures together you must obtain data cables You...

Page 15: ...Make sure that you do not have any overlapping channels in order to control each ACT Fresnel correctly If two or more ACT Fresnels are addressed similarly they will work similarly Controlling After ha...

Page 16: ...15 Order code 34011 ACT Fresnel 50 WW Main Menu Overview...

Page 17: ...igate through the menus or to increase decrease numeric values Use the ENTER button to open the desired menu to confirm your choice or to set the currently selected value Note If no button is pressed...

Page 18: ...vior of the device in case of a DMX signal failure 01 Press the UP DOWN buttons to select one of the following 3 options Manually Defined The device will use the dimmer value selected with the manual...

Page 19: ...ation Manually Defined The dimming of the light output is controlled manually via the menu Refer to One ACT Fresnel Manual Control on page 11 for more information 03 Press the ENTER button to confirm...

Page 20: ...justment range is between 0 and 30 from low to high contrast 5 Fixture Test In this menu you can perform test of the device s parameters and adjust manually the dimmer and strobe values 01 Press the U...

Page 21: ...Firmware Version Shows the current firmware version 02 Press the ENTER button to confirm the selection and view the information 7 Special Functions In this menu you can reset the device s settings to...

Page 22: ...frequency 85 89 No strobe 90 104 Strobe slow close fast open from high to low frequency 105 109 No strobe 110 124 Random strobe from high to low frequency 125 129 No strobe 130 144 Random strobe fast...

Page 23: ...c power source 02 Insert a screwdriver into the slot of the fuse cover Turn the fuse holder counterclockwise The fuse holder will come out 03 Remove the used fuse If brown or unclear it is burned out...

Page 24: ...data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in the DMX...

Page 25: ...Warm White COB LED Dimmer 0 100 Strobe effect Yes Zoom Manual Beam angle 10 58 manual adjustment Output 10 3430 lx 2 m 58 402 lx 2 m Color temperature 3200 K Light quality CRI 98 Housing Extruded alu...

Page 26: ...25 Order code 34011 ACT Fresnel 50 WW Dimensions...

Page 27: ...26 Order code 34011 ACT Fresnel 50 WW...

Page 28: ...2020 Showtec...

Reviews: