13
Order code: 34011
ACT Fresnel 50 WW
Fixture Linking
You will need a serial data link to run light shows of one or more fixtures using a DMX-512. The combined
number of channels required by all the fixtures on a serial data link determines the number of fixtures the
data link can support.
Important:
Fixtures on a serial data link must be daisy-chained in a single line. To comply with the
EIA-485 standard, no more than 30 devices should be connected on one data link.
Connecting more than 30 fixtures on one serial data link without the use of an optically
isolated DMX splitter may result in deterioration of the digital DMX signal.
Maximum recommended DMX data link distance: 100 meters
Maximum recommended number of fixtures on a DMX data link: 30 fixtures
Data Cabling
To link fixtures together, you must obtain data cables. You can purchase DAP Audio certified DMX cables
directly from a dealer/distributor or construct your own cable. If you choose to create your own cable,
please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic
interference.
DAP Audio DMX Data Cables
●
DAP Audio 110 Ohm cable with digital signal transmission. Order code FL0975 (0,75 m),
FL09150 (1,5 m), FL093 (3 m), FL096 (6 m), FL0910 (10 m), FL0915 (15 m), FL0920 (20 m).
●
DAP Audio DMX Terminator 3-pin. Order code FLA42.
Note: Use of 3-pin XLR audio cables for DMX data transmission might lead to signal degradation and
unreliable operation of the DMX network.