background image

Save This Guide For Future Reference

   

PN: 006.9140.20 

    January 

2019

Oxygen Therapy Plus Door

A S S E M B LY   G U I D E

Oxygen Therapy Plus Door

(30x30 Door Configuration Shown)

(Cage NOT Included)

Summary of Contents for Oxygen Therapy Plus Door

Page 1: ...Save This Guide For Future Reference PN 006 9140 20 January 2019 Oxygen Therapy Plus Door ASSEMBLY GUIDE Oxygen Therapy Plus Door 30x30 Door Configuration Shown Cage NOT Included...

Page 2: ...F United Kingdom PHONE 44 1446 77 20 41 FAX 44 1446 77 36 68 EMAIL quality shor line co uk WEB ADDRESS SHOR LINE co uk Shor Line may provide instructions that supplement or supersede this Guide at any...

Page 3: ...en Therapy Plus Door Configurations 7 Cage Door Removal Single Door 7 Cage Door Removal Double Door 8 Double Door Latch Bar Removal 8 Oxygen Therapy Plus Door Installation 10 Oxygen Therapy Plus Door...

Page 4: ...jury Important Information Symbol Indicates information considered important but not directly hazard related Personal Protective Equipment PPE PPE refers to protective clothing or other equipment desi...

Page 5: ...ng assembly installation and moving equipment Oxygen Therapy Plus Doors and Stainless Steel Cages have sharp edges stay clear of and DO NOT TOUCH exposed edges which if not avoided could result in SER...

Page 6: ...cal Oxygen Therapy Plus Door Double Door Conversion Kit JAMB SEAL HEAD SEAL ADJUSTABLE VENTS LATCH BAR W SEALS CONVERSION DOOR Shipment Inventory At arrival unpack and inspect the shipment to ensure i...

Page 7: ...ONVERSION DOOR Part Description Single Door Conversion Kit 914 2424 20 DOOR 24X24 OXYGEN THERAPY PLUS 914 2430 20 DOOR 24X30 OXYGEN THERAPY PLUS 914 2436 20 DOOR 24X36 OXYGEN THERAPY PLUS 914 3030 20...

Page 8: ...8 310 1181 00 WASHER O2 DOOR ALUMINUM 1 09 310 0209 00 ADAPTER HUMIDIFIER 1 10 061 1008 01 10 32X 875 RD HD PHILLIPS SS 2 11 063 1000 00 10 32 HX NUT NYLOCK SS 2 12 195 1377 00 O2 ANALYZER OXYGEN THER...

Page 9: ...062 2510 05 250 20 X 1 000 TRUSS HD PHIL SS 4 07 065 2500 00 250 FL WASH SAE SS 4 08 064 2500 02 250 20 HX NUT NYLOCK SS 4 09 714 0002 00 WLDMNT LATCH PIN TYPE 4 DOOR 2 10 062 2510 05 250 20 X 1 000...

Page 10: ...procedures listed in this manual Doing so can scratch product surfaces and or cause hardware to fail Do NOT over tighten hardware Cage Door Removal Single Door Door hinges may vary depending on the ca...

Page 11: ...R to MODERATE INJURY STEP 3 Repeat Steps 1 and 2 to remove the second door STEP 4 Clean and store unused grill doors and hardware for future re installation if needed Double Door Latch Bar Removal Sho...

Page 12: ...P 2 Lift the latch bar upward to clear the keyhole slots located at the top of the latch bar See FIGURE 2 7 FIGURE 2 7 Latch Top Keyhole Slot SLIDE UP FIGURE 2 8 Remove Latch Top REMOVE FROM LATCH PIN...

Page 13: ...s on the head seal top with the hardware screws Slide the head seal under the trim plates Secure the head seal by tightening the top trim plate screws See FIGURE 2 12 FIGURE 2 11 Jamb Seal Installatio...

Page 14: ...STEP 2 Align the slots on the jamb seal side with the hardware screws Slide the jamb seal under the trim plates strips and hardware Secure the jamb seal with the center screw do NOT fully tighten See...

Page 15: ...the hinges See FIGURE 2 20 The hinge bushings have a flat side that slide through the opening in the hinge assembly The flat side of the bushings must be facing away from the cage to align with the h...

Page 16: ...oing so can scratch product surfaces and or cause hardware to fail FIGURE 3 1 Oxygen Therapy Plus Door 30x30 SD 48x30 DD Shown SINGLE DOOR CONFIGURATION DOUBLE DOOR CONFIGURATION NOTE STAINLESS STEEL...

Page 17: ...ygen Analyzer The oxygen analyzer is an optional component for the O2 Door sold separately The oxygen analyzer can be used to spot check oxygen concentration within the O2 therapy treatment cage Refer...

Page 18: ...he cage door avoid using chemicals around meter Adjustable Vents Vents located on the face of the cage door can be rotated to increase or decrease the openings adjusting the airflow into and out of th...

Page 19: ...bar down to the lowest position on both guides STEP 5 Install the latch assembly to the cage frame tighten screws to secure the latch to the frame See FIGURE 3 12 FIGURE 3 11 Latch Assembly Rotate RI...

Page 20: ...sure the meter is reinstalled on the backside cage side of the door Do NOT attempt to remove the meter by sliding it out of the bracket while still attached to the door may scratch the door surface ST...

Page 21: ...F OF WASHER Ensure the humidifier holder is secured to the bottom two holes The top two screw holes are not used for this procedure See FIGURE 3 22 3 23 FIGURE 3 22 Holder Front Side USE HOLES ON LOWE...

Page 22: ...lot FIGURE 3 17 Hinge Bushing PRY TWIST TO UNSNAP FIGURE 3 18 Hinge Bushing SEPARATE AND FLIP ON END STEP 1 Use a flathead screwdriver to pry separate the two hinge bushing halves See FIGURE 3 17 3 18...

Page 23: ...Scheduled preventive cleaning should include but not limited to daily or weekly inspections and cleaning of products to prolong its longevity and to help maintain finishes Safe Cleaning Practices Use...

Page 24: ...n compliance with Shor Line s Return Policy If containers do not show evidence of damage there may be concealed damage Customer must report any concealed damage within 15 days after receipt of the shi...

Page 25: ...r the aforementioned product satisfaction policy SHOR LINE makes no other warranty or guarantee of any kind whatsoever whether expressed or implied statutory or otherwise including but not limited to...

Page 26: ...66105 USA PHONE 800 444 1579 LOCAL 913 281 1500 FAX 913 281 5339 EMAIL guides shor line com WEB ADDRESS SHOR LINE com SHOR LINE LIMITED Vale Business Park Llandow Vale of Glamorgan CF71 7PF United Kin...

Reviews: