10
Oxygen Therapy Plus Door Installation
The O
2
Door and components are packaged in
separate boxes. Unpack and organize the door
components for assembly and installation.
Enlist help and USE SAFE LIFTING
PRACTICES during assembly, installation and
moving equipment.
Keep hands clear of possible pinch areas when
assembling parts, which if not avoided, could
result in MINOR to MODERATE INJURY.
STEP 1:
Loosen trim plates, hinges, latch bar and trim strips. Do NOT remove screws or
hardware. See FIGURE 2.10
STEP 2:
Align the slots on the jamb seal (side) with the hardware screws. Slide the jamb
seal under the trim plates, strips and hardware. Secure the jamb seal with the
center screw, do NOT fully tighten. See FIGURE 2.11
STEP 3:
Repeat STEP 2 for opposite side jamb seal.
STEP 4:
Align the slots on the head seal (top) with the hardware screws. Slide the head
seal under the trim plates. Secure the head seal by tightening the top trim plate
screws. See FIGURE 2.12
FIGURE 2.11 - Jamb Seal Installation
FIGURE 2.12 - Head Seal Installation
STEP 5:
Tighten all trim plates, strips and hardware to secure the jamb and head seals
in place.
STEP 6:
Install the O
2
Door by holding the door hinge pins/bushings above the cage
hinges at a 90
°
angle to the face of the cage. Slide the hinge pins/bushings down
into the hinges. See FIGURE 2.13
The hinge bushings have a flat side that slide
through the opening in the hinge assembly. The
flat side of the bushings must be facing away
from the cage to align with the hinges. The
hinge bushing must fully seat into the hinge for
proper operation.
STEP 7:
Close the door, check latch operation and
adjust alignment to ensure the O
2
Door
latches correctly.
FIGURE 2.10 - Loosen Trim
LOOSEN, DO NOT REMOVE
FIGURE 2.13 - Door Installation
PERPENDICULAR TO CAGE FACE
SECTION TWO