background image

{6}

;

Section 2: General Safety Precautions

When using electrical equipment, basic safety precautions must be followed, including: 
 

 

For best results place animal in the center of the Warming Pad.

• 

Read all instructions before using this equipment. Improper installation could cause product malfunction.

• 

This equipment must be grounded. Connect only to properly grounded outlet. See 

Grounding Instructions and  

 Installation 

below.

• 

Install or locate this equipment only in accordance with the provided installation instructions.

• 

Use this equipment only for its intended use as described in this guide.

• 

This equipment should not be used by children.

• 

Do not operate this equipment if it has a damaged cord or plug, if it is not working properly, or if it has been   

  dropped or damaged in any manner.

• 

Do not cover or block any opening on the equipment.

• 

Do not use outdoors.

• 

Do not use in an oxygen enriched environment or near oxygen emitting equipment.

• 

Do not immerse cord, plug or equipment in water.

• 

Do not let cord hang over edge of table or counter.

• 

Turn equipment off at switch before unplugging from wall outlet.

• 

When unplugging equipment, grip plug, not cord.

• 

Store equipment promptly after each use to prevent accidents from tripping over power cord or pulling equipment  

  off of work surface.

• 

Contact Shor-Line for examinations, repairs or adjustments.

 

{Grounding Instructions & Installation}

This equipment must be grounded. In the event of an electrical short circuit, grounding reduces the risk of electric 
shock by providing an escape wire for the electric current. This equipment is equipped with a cord having a 
grounding wire with a grounding plug. The plug must be plugged into an outlet that is properly installed and 
grounded.

 

Improper use of the grounding plug can result in risk of 

electric shock.

Consult a qualified electrician or service person if the grounding 

instructions are not completely understood, or if doubt exists as to 
whether the appliance is properly grounded.

For personal safety, this equipment must be properly grounded 
by being plugged directly into a 120 Volt, 50/60 Hz, or 240 Volt, 

50/60 Hz (United Kingdom and Europe only), grounded polarized 

three prong outlet (see voltage label on product). DO NOT, under 

any circumstances, cut or remove the third (round) prong from the 

power cord (Fig. 2.1).

The use of an extension cord, even a heavy duty cord, is not 
recommended because of potential safety hazards.

Where a standard two-prong wall receptacle is encountered, it is 
the personal responsibility and obligation of the consumer to have 
it replaced with a properly grounded and polarized wall receptacle 

in accordance with the National Electrical Code.

Where local codes permit, a TEMPORARY CONNECTION may be made to a properly grounded two-prong wall 

receptacle by the use of an adapter which is available at most local hardware stores (Fig. 2.2).

Attaching the adapter ground terminal to the cover screw of the electric outlet, does not ground the equipment un-
less the cover screw is grounded through the building wiring. If there is any doubt whether the wall receptacle is 

properly grounded, have it checked by a qualified electrician.

 

       Fig. 2.2

 

       Fig. 2.1

Summary of Contents for 912.1000.05

Page 1: ...06 9120 01 Updated 3 27 15 To reduce the risk of injury the user must read and understand this guide before installation of this product This product is for animal use only We do not condone this prod...

Page 2: ...ndone this product for other uses To reduce the risk of injury the user must read and understand this guide before installation of this product Continuous low heat in one area may burn a patient Impro...

Page 3: ...nnection 8 Cable Extension 9 Mounting the Controller to the Cage Door 9 Moving Warming Pad 10 Section 4 Functions 11 Section 5 Maintenance Cleaning 12 Section 6 Important 12 Section 7 Services Terms C...

Page 4: ...edures may result in a void of all Shor Line warranties Step 3 Remove and separate all contents from the shipping containers Use the Packing Slip to ensure nothing has been lost Step 4 Check content f...

Page 5: ...exceeding the safety shut down limit the Alert mode will sound bringing the Warming Pad to the technician s attention by both sound and a red light and will automatically shut down and start a cool do...

Page 6: ...f electric shock by providing an escape wire for the electric current This equipment is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that...

Page 7: ...imals should not be allowed access to the Warming Pad without careful supervision because the Warming Pad could be damaged The Warming Pad can be used by placing the unit under the patient while lying...

Page 8: ...using a steel armored cable with straight multi pin connectors and a bulkhead multi pin connector The cable contains industry standard alignment tools Key and Key Way to assist you Once the Warming P...

Page 9: ...onal armored cables please call our Technical Services Department at 800 444 1579 Mounting the Controller to the Cage Door NOTE Do not plug in power cord until controller has been mounted Once the cab...

Page 10: ...steps Step 1 Ensure the Warming Pad is powered off Step 2 Unplug power cord from outlet Step 3 Remove controller for cage door Step 4 Disconnect cable attached to the bulk head connector by turning c...

Page 11: ...s for a total of 8 beeps For the last minute of any time cycle the Stand By light will illuminate a flashing yellow and a double beep will occur every 10 seconds alert The Warming Pad is factory set a...

Page 12: ...k head connector counter clock wise Step 3 The Warming Pad may be wiped using warm soapy water or disinfectant on a soft damp cloth Special care should be taken to ensure the bulk head connectors are...

Page 13: ...ecifications Any quotation whether written or oral is not an offer to contract or acceptance of an order Similarly neither a price list nor a catalog constitutes an offer to sell or contract but are p...

Page 14: ...RANTEE OF ANY KIND WHATSOEVER WHETHER EXPRESS OR IMPLIED STATUTORY OR OTHERWISE INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF FITNESS AND OR MERCHANTABILITY THE ABOVE LIMITED WARRANTY CONSTITUTES...

Page 15: ...Buyer agrees that no goods covered by this contract shall be used in any manner violative of any laws of the United States whether state or federal or local ordinance and no such goods shall be distr...

Page 16: ...Shor Line Schroer Manufacturing Co 511 Osage Avenue Kansas City KS 66105 U S A 800 444 1579 toll free local fax 913 281 1500 913 281 5339 www shor line com...

Reviews: