1.  With cord disconnected from receptacle and tank cover removed, turn tank upside down so that 

the bottom is facing up with the inlet towards you 

(Figure 1).

 

2.  Insert caster into bottom of tank by placing stem of 

caster into holes provided. Apply pressure and twist-

ing motion until casters snap into place 

(Figure 2).

3.  Mount wheel onto axle with smooth face of wheel 

outward 

(Figure 3).

4.  Insert wheel plug through wheel and axle housing 

turning wheel plug until it seats flush with outside of 

wheel 

(Figure 4).

5.  Insert screw provided through back of axle housing 

(Figure 5).

 

6.  Slide axle housing into dovetail slot at rear of tank: 

axle housing is tapered and should slide into dove-

tail slot without excessive force 

(Figure 6). 

Tighten 

screw.

7.  Repeat steps 3 through 6 for other wheel assembly.
8.   Return tank to upright position.

ACCESSORY BASkET ASSEMBLY

(Not standard with all models)

1.  With rear of tank facing you, take accessory basket 

and position with tabs facing rear of tank 

(Figure 7).

2.  Insert tabs of accessory basket into slots on rear of 

tank 

(Figure 8).

3.  Press down until basket is secured into place.

7

8

TOOL HOLDER ASSEMBLY

(Not standard with all models)

1.  Replace tank cover and apply pressure with thumbs to each latch until it 

snaps tightly in place. Make sure both lid latches are clamped securely. 

2.  With rear of unit facing you, take tool holder and position it with the tabs fac-

ing rear tank cover 

(Figure 9).

3.  Press tabs of tool holder into the slots on mounting lugs on rear of tank 

cover  

(Figure 10).    

4.  Press down until tabs snap into place.

NOTE: TOOL HOLDER NOT COMPATIBLE WITH ACCESSORY BASkET.

9

10.

INSTALLING FOAM SLEEVE AND

REUSABLE DRY FILTER

WARNING

 – ALWAYS DISCONNECT THE PLUG FROM THE 

WALL OUTLET BEFORE REMOVING THE TANk COVER. 

     

CAUTION

 – kEEP FILTERS CLEAN

EFFICIENCY OF ThE VACUUM IS LARGELY DEPENDENT ON ThE FILTER. A CLOGGED FILTER 

CAN  CAUSE  OVERhEATING  AND  POSSIBLY  DAMAGE ThE  CLEANER.  ChECK ThE  FILTER 

PERIODICALLY AND REPLACE AS REqUIRED.

DRY PICk UP

To pick up dust and dry material, you must install foam sleeve and reusable dry filter to ensure 

proper filtration. 

NOTE: For E87S model filter retainer must be installed.

 If the vacuum has been 

used to pick up liquids, the foam sleeve must be cleaned and dried before installing for dry pick up.

With tank cover in an upside down position, slide foam sleeve down over lid cage pulling until foam 

sleeve completely covers lid cage 

(Figure 11)

.  

NOTE:

 Bottom of foam sleeve must be positioned 

on the OUTSIDE of groove around lid cage for the reusable dry filter to fit properly 

(Figure 12, 13)

Center the reusable dry filter on lid cage 

(Figure 14)

, slide mounting ring down over filter until ring 

is positioned against the ribs of the lid cage 

(Figure 15)

.  The reusable dry filter should always be in 

position over the foam sleeve for dry pick up. To remove the filter for cleaning, remove mounting ring 

and filter from lid cage 

(Figure 16)

.  To clean the reusable dry filter, shake off excess dirt and dust or 

(depending on the condition of the filter) rinse with water. Allow the filter to dry completely and re-install. 

DO NOT MACHINE WASH OR DRY.
IMPORTANT:    BEFORE  INSTALLING  REUSABLE  FILTER  BE  SURE  THAT  FOAM  SLEEVE  IS 

OUTSIDE OF GROOVE AND AROUND LID CAGE (Figure 12, 13).
NOTE:  ENSURE THAT THE MOUNTING RING IS COMPLETELY SECURE AND IN POSITION BY 

PRESSING DOWN FIRMLY AROUND THE RING IN SEVERAL PLACES. BE SURE THE REUSABLE 

(Not standard with all models)

DRY  DISC  FILTER  COMPLETELY  COVERS  THE  FOAM  SLEEVE.  CHECk  TO  ENSURE  THAT  ALL 

EDGES OF THE REUSABLE DRY FILTER ARE SECURE UNDER THE MOUNTING RING.

INSTALLING THE CARTRIDGE FILTER

(Not standard with all models)

The cartridge filter can be used for wet or dry pick up; installation is the 

same for both. For dry pick up be sure the opening of the inlet deflector 

is facing the tank bottom 

(Figure 17)

. Use the cartridge filter in position 

over the lid cage for most general dry material pick up.  With the tank 

cover  in  an  upside  down  position,  slide  the  cartridge  filter  down  over 

the lid cage, pushing until the filter seals against the cover 

(Figure 18)

Place filter retainer into the top of the cartridge filter, hold the tank cover 

with one hand, turn the handle on the filter retainer clockwise to tighten, 

locking the filter into place 

(Figures 19 & 20)

.  To remove the filter for cleaning, again hold the 

tank cover and turn the filter retainer counter-clockwise to loosen and remove, slide the cartridge 

filter off the lid cage 

(Figures 21 & 20)

.  To clean the cartridge filter shake or brush off excess 

dirt or rinse (from the inside of the filter) with water, dry completely (approximately 24 hours) and 

re-install. 

(Figures 23 & 24)

.  

Note:

 If the filter has been used for wet pick up, it must be cleaned 

and dried before using for dry pick up.

17

11

12

13

14

15

16

18

19

TIGHTEN

20

21

22

24

LOOSEN

23

INSTALLING THE

DISPOSABLE FILTER BAG

(Not Standard with All Models)

1.   Use for dry pick up only. Use in conjunction with cartridge filter for picking up soot, cement, 

plaster or drywall dust.

2.  With cord disconnected from receptacle, pull latches in an outward motion and remove tank cover.
3.   Unscrew hose locking-nut and remove hose from inlet 

(Figure 25).

4.   Remove inlet deflector from deflector guide 

(Figure 26).

 

NOTE:

 hose must be removed before 

inlet deflector can be taken out.

5.   With the opening of the inlet deflector facing the bottom of the filter bag, slide collection bag collar 

over deflector matching notches of bag collar to tabs on inlet deflector, bag will only fit properly 

one way 

(Figure 27).

6.   Slide deflector with collection bag attached into deflector guide 

(Figure 28).

7.   Reinsert hose into inlet and tighten locking-nut 

(Figure 29).

8.   When secured in place, expand bag and position around the inside of tank.

25

26

27

2

1

3

4

5

6

28

29

Summary of Contents for E87 Series

Page 1: ...rporation All Rights Reserved 87544 32 Shop Vac Corporation 2011 Tous Droits R serv s 2011 Shop Vac Corporation Todos los Dereches Reservados DANGER Never operate this unit when flammable materials or...

Page 2: ...operly grounded outlet box cover Whenever the adap tor is used it must be held in place by a metal screw In Canada the use of a temporary adaptOr is not permitted by the Canadian Electrical code Make...

Page 3: ...position over the foam sleeve for dry pick up To remove the filter for cleaning remove mounting ring and filter from lid cage Figure 16 To clean the reusable dry filter shake off excess dirt and dust...

Page 4: ...liquids As the level of the liquid rises in the tank an internal float rises until it seats itself against a seal at AUTOMATIC SUCTION SHUT OFF LUBRICATION No lubrication is necessary as the motor is...

Page 5: ...ou en fonctionnement d branchez l appareil lorsqu il n est pas utilis CONSERVEZ CES INSTRUCTIONS Cet aspirateur ne doit tre branch que sur un circuit aliment en courant lec trique de 120 volts Le cor...

Page 6: ...e la prise de courant et le couvercle de la cuve tant d pos tourner la cuve l envers de fa on que son fond soit orient vers le haut et l orifice d orientation soit orient vers soi Figure 1 2 Ins rez l...

Page 7: ...air situ sur l int rieur de la cuve de l aspirateur GUIDE POUR LE CHOIX DU FILTRE DIMENSIONS 18 9 30 3 L 5 8 Gal U S 37 8 53 L 10 14 Gal U S 56 8 83 2 L 15 22 Gal U S 90671 90661 90532 90672 90662 905...

Page 8: ...NT L ASPRATEUR POUR NE PAS SUBIR DES BLESSURES CORPORELLES ET NE PAS ENDOMMAGER DAVANTAGE L ASPIRATEUR R PARER L ASPIRATEUR AVANT DE LE R UTILISER GARANTIE DE Trois 3 ANS POUR UN USAGE M NAGER Votre a...

Page 9: ...ieza dependiendo de lo que usted requiera para limpiar a las varillas de extensi n Tuerza ligeramente para apretar la conexi n Figura A 8 Enchufe el cable al tomacorriente de pared Su aspiradora est l...

Page 10: ...do hacia la parte superior del dep sito Figura 30 Puede ocurrir una condensaci n si el deflector de entrada no est insertado adecuadamente La condensaci n en el aire de emisi n puede ocurrir si el fil...

Page 11: ...ra etc por posibles obstrucciones y remu valas si es que existen Bruma en el aire expul sado Filtro saturado Reemplace un filtro saturado por un filtro seco DESPERFECTOS ADVERTENCIA UTILICE SIEMPRE PR...

Reviews: