-26-
Model W1867/W1868/W1869 (For Machines Mfd. Since 11/18)
SE
TU
P
Test.Run
Serious. injury. or. death. can. result.
from. using. this. machine. BEFORE.
understanding. its. controls. and. related.
safety.information..DO.NOT.operate,.or.
allow.others.to.operate,.machine.until.
the.information.is.understood..
DO. NOT. start. machine. until. all.
preceding.setup.instructions.have.been.
performed..Operating.an.improperly.set.
up. machine. may. result. in. malfunction.
or. unexpected. results. that. can. lead.
to. serious. injury,. death,. or. machine/
property.damage.
Once assembly is complete, test run the machine to
ensure it is properly connected to power and safety
components are functioning properly.
If you find an unusual problem during the test run,
immediately stop the machine, disconnect it from power,
and fix the problem BEFORE operating the machine again.
The
Troubleshooting
table in the
SERVICE
section of this
manual can help.
To.test.run.machine,.do.these.steps:
1.
Clear all setup tools away from machine.
2.
Lock all swivel casters on base stand.
3.
Connect machine to dust-collection system or place
covers over inlet adapter ports.
IMPORTANT:
DO NOT operate dust collector without
first connecting it to a dust-collection system or
covering an inlet adapter port. Otherwise the lack
of airflow resistance will cause the motor to operate
at full amperage load, which could trip your circuit
breaker or blow a fuse.
4.
Press Emergency Stop button in, and connect
machine to power.
5.
Twist Emergency Stop button clockwise until it
springs out (see
Figure.33
). This resets switch so
machine can start.
6.
Standing away from intake port, press green "I"
button to turn machine
ON
. Verify motor starts up
and runs smoothly without any problems or unusual
noises.
7.
Press Emergency Stop button to turn machine
OFF
.
8.
WITHOUT resetting Emergency Stop button, try
to start machine by pressing the "I" button. The
machine should NOT start.
— If machine
does not
start, the Emergency Stop
button is working correctly.
— If machine
does
start, immediately turn it
OFF
and disconnect power. The Emergency Stop button
is NOT working properly and must be corrected
before further using the machine.
9.
To test remote control operation,
press green remote button to turn
motor
ON
. The motor should run
smoothly with little or no vibration or
rubbing noises.
10.
Press red remote button to turn motor
OFF
.
— If the machine does not shut off
with the remote control, press
the Emergency Stop button to
turn machine
OFF
. Refer to
Troubleshooting
on
Page.43
to
correct any problems with the
remote control unit before further
using it again with the machine.
Figure.33.
Resetting Emergency Stop
button.