23(44)
3.6 Combined Installation of Modules
1) Disassembly the sideplates around the machine, calibrate the cooling water
inlet to combine the modules. Use rubber soft pipe to connect the module's
chilling water pipe.
2) The non-exist end of the cooling water pipe should be fixed by flange.
3) Refers to wiring diagram to tandem the communication line to next
submodule, the communication line of which tandems to next submodule
thereby.
Picture 3-6: Combined Installation of Modules
3.7 Essentials for Electric Wiring
1) The electricity supply should use special branch circuit.
2) Wiring work should be conducted according to relevant national electric
standards and grounding.
3) Refer to wiring diagram to conduct wiring work. Lock up every contact screws,
do not let them loosen.
4) The voltage has to be stable when in operation, take all the voltage down fall
into consideration, the unit working voltage should maintain at
±
10% within
rated voltage. Over high or over low voltage will bring bad effect to the unit.
5) The length of the power cable must ensure the voltage gap value between
the head and tail of cable be less than
±
2% within rated voltage, if the length