Pat AIS and Pat LSS. (Only in E1 mode)
SDH part: including LOS, LOF, RS TIM, MS AIS, MS RDI, AU AIS, AU LOP, HP UNEQ, HP RDI,
HP TIM, HP PLM, LTI, Pat AIS, Pat LSS, TU AIS (grey when set up as C4), TU LOP (grey when set
up as C4), LP UNEQ (grey when set up as C4), LP RDI (grey when set up as C4), RFI (grey when
set up as C3 or C4), LP TIM (grey when set up as C4) and LP PLM (grey when set up as C4).
In any interface, click on the “Start” shortcut key to start synchronous counting and operation.
Click on ”Stop” button to stop. Click on the “Chart” shortcut key to generate a dynamic histogram of
alarm test results in this interface directly.
6.2. Error Code Test Result
For error code test result interface, see Figure 6-3 as follows:
Figure 6-3 Error Code Test Result
“Error type”:
PDH part: including error code counting, sec & rate of ECOD, EFAS, ECRC, REBE and EBIT.
(Only in E1 mode)
SDH part: including error code counting, sec & rate of B1, B2, MRAI, HP B3, LP B3 (grey when
set up as C12 or C4), HP REI, LP REI (grey when set up as C4), EBIT and BIP2 (grey when set up
as C3 or C4).
In any interface, click on the “Start” shortcut key to start synchronous counting and operation.
Click on the exit button to stop. Click on the “Chart” shortcut key to generate a dynamic histogram of
error test results in this interface directly.
6.3. Pointer Test Result
For pointer test result interface, see Figure 6-4 as follows: