![ShinewayTech DTA-SDH/155 Operating Manual Download Page 25](http://html1.mh-extra.com/html/shinewaytech/dta-sdh-155/dta-sdh-155_operating-manual_1257993025.webp)
DTA-SDH/155
Operating Manual
Shineway Technologies, Inc.
25
4.2. Regular Overhead Test
Including HOPOH and LOPOH. See Figure 4-3 as follows:
Figure 4-3 Regular Overhead Test
The contents include the transmission and receiption of S1, G1, H4, V5, K1, K2, K3, K4 and C2.
The ”Set” shortcut key can set up an input value or parameter of “Transmit value”. “Receive value”
is not controlled by the shortcut key and can receive in real time.
4.3. Pointer Value Test
For pointer value test, see Figure 4-4 as follows:
Figure 4-4 Pointer Value Test
The contents including: “Pointer type”: AU and TU, with a default value of AU.
“NDF”: ON, OFF, with a default value of OFF, where “ON” can be inserted only one time.
Otherwise, the point may be lost. During a test, OFF can be selected.
“Setup SS BITS”: 10.
“Transmit value of pointer“: scope of setup AU 0-782, TU3 0-764, TU12 0-139, with a default
value of 128.