DTA-SDH/155
Operating Manual
Shineway Technologies, Inc.
29
Figure 4-8 Pointer Adjusting Test
“Start time” refers to the time of system when the “Start” shortcut key is clicked on. “Duration” is
continual time keeping after “Start time”. Click on the “Start” shortcut key again to stop.
“Insert mode”: repetitive burst, scope of setup AU 0-2000, TU3 0-2000, TU12 0-500, with a
default value of 500.
“Pointer event “: AU +PJ, AU –PJ, AU INV, TU +PJ, TU –PJ, TU INV.
The “Set” shortcut key can set up all the input values or parameters. Once it is set up, “Insert
mode” changes to the current mode (insert pointer) instead of the original mode with a display on
the upper part of the screen. Then, the ”Insert” shortcut key can implement the insert. The default
value is AU+PJ.