DTA-SDH/155
Operating Manual
Shineway Technologies, Inc.
33
“Start time” refers to the time of system when the “Start” shortcut key is clicked on. “Duration” is
continual time keeping after “Start time”. Click on the “Exit” shortcut key to stop.
“Current”: indicating the measuring result of current RTD.
“Offset”: scope of setup 0-9999, with a unit of us, and moreover, “Set Offset” can be added with
the value of “Current”.
“Set Offset”: add “Current” to “Offset”.
“State”: measuring, and measured.
“Pat”: indicating current alarm status of SYNC, AIS, EBIT and SLIP.
Test starts once in the menu, with a display of test result in “Current” and “State” column. Pay
attention to the interlocking with the ”Start” shortcut key.
5.5. Tributary Scan Test
For tributary scan test, see Figure 5 -6 as follows:
Figure 5-6 Tributary Scan Test
“Tributary scan”: 1-63 and *(when the receiving part of “Test configuration“ is E1 or VC12), 1-3
(when the receiving part of “Test configuration“ is E3 or C3).
“TUG3”: 1-3 and *, “TUG2”: 1-7 and *, “TU12”: 1-3 and *(when the receiving part of “Test
configuration“ is E1 or VC12).
Click on the “Scan” shortcut key to enter the scan result interface directly. The default value is
to select all.