10
7. Operating Procedures (Light Tower)
WARNING: TIPPING OVER
Always be sure to install this SBL750L-M Light Tower to Generator/Trailer set
before use.
Lower the mast if using in strong wind that causes the lamp fitting to sway
severely.
Although the mast can withstand wind speeds up to 15 m/s when the mast is
completely extended (with the balloon standing vertically), the balloon fabric
can become deformed in wind speeds of 12 to 14 m/s and entangled in the
lamp guard. Never use this equipment in wind speeds of 10 m/s (roughly the
wind speed at which the balloon fabric starts to deform) or more in order to
prevent damage from LED heat and provide safety by preventing the LED
from tipping over.
Use on a level surface with a solid foundation. If it is absolutely necessary to
use on an inclined surface, adjust Light Tower/Generator so that it is leveled
by setting blocks under the wheels to avoid inclining mast (standing vertically).
WARNING: ELECTRIC SHOCK
Do not touch this Light Tower during operation if equipment or your body is
wet.
Do not plug or unplug the power plug with a wet hand.
Do not use the power cord if it is damaged or worn.
Do not connect the power cord to the outlet when performing any check or
maintenance of the LED and other parts.
WARNING: IMPAIRED EYESIGHT
Do not work for an extended period of time near the LED and do not look
directly into the LED.
Do not turn on the LED with the balloon fabric removed. Looking directly into a
LED light source can cause dizziness.
CAUTION: ELECTRIC SHOCK
Do not sprinkle water on the equipment and do not use where exposed to rain.
<Note>
Using in wind speeds from 12 to 14 m/s can result in the balloon fabric becoming
deformed and entangled in the lamp guard, resulting in damage from the heat of the LED.
Lower the mast to use the Light Tower when the air wind speed is 10 m/s (roughly the
wind speed at which the balloon fabric starts to deform) or more. Stop using if the balloon
fabric will deform even if the mast has been lowered.
When storing at outside, be sure to always secure the balloon fabric by using the buckle
and cover the equipment. This is to prevent the service life of the balloon fabric from
being reduced by the wind and ultra-violet rays.
Do not connect the generator to any other electrical equipment while the balloon Light
Tower generator is lit up. Using for electric tools or other equipment at the same time
causes a high current to flow when started, causing the LED to go out.