- 11 -
< Caution >
•
The battery charge monitor cannot detect the degradation of the battery nor the
battery fluid level. Check the battery fluid level periodically.
(
Refer to
『
6-5
.
Checking
Battery
』
)
(3) Oil Pressure Monitor Lamp
Danger : Injuries
•
Close all doors and place locks during operating this equipment, to avoid
injuries by unintentional contact with cooling fan and fan belt.
Caution : Burns
•
Do not touch the engine and muffler during operation and immediately
after stopping the equipment, for the temperature could reach extremely
high temperature.
•
When checking engine oil, always stop the engine, and wait until the
engine cools down. If you open either the oil gauge or the oil filter cap
during operation, hot oil may spilled out.
When the engine oil pressure drops during operation, the oil pressure monitor lamp
will flash, and the automatic shutoff will be engaged.
When this symptom occurs, check the engine oil level, and replenish to the
maximum level if needed.
< Caution >
•
The engine oil pressure monitor cannot detect the deterioration of engine oil itself.
Check the engine oil periodically, and change if needed.
(
Refer to
『
11
.
Inspection
and Maintenance
』
)
•
Check the fuse next, when the abnormality, other than
『
WATER TEMP
』
,
『
CHARGE
』
or
『
OIL PRESS
』
is detected.
If the fuse is burned out, consult with authorized distributor, as there may be an
abnormality of electrical components or wiring which would be inspected.
5-7
.
.
.
.
Remote Control(Option)
The equipment incorporates with remote control receptacle feature.
Remote control boxes are the optional parts.
Remote control operation is available by connecting the compatible remote
controller to the receptacle. Adjust the welding current at the remote area from the
machine.
<
Caution >
•
When the remote control box is connected, the current adjustment dial of the
equipment’s front panel will not work.
•
When the plug of remote control box has disconnected while welding, the current
adjustment dial of the equipment will work. It may affect to increase or decrease
the current accidentally.
REMOTE
CONTROL
RECEPTACLE
REMOTE
CONTROL BOX
Summary of Contents for DGW300M