- 28 -
Symptoms
Possible cause
Corrective actions
Excessive
welding arc
1
.
Wrong current adjustment dial
position
1
.
Turn the dial
counterclockwise
No AC output
1
.
The breaker position to
『
OFF
』
1
.
Turn to
『
ON
』
AC output is
weak
1
.
Wrong frequency
2
.
The rated current of the load
exceeds the rated output
3
.
Simultaneous use of welding
and Generating
1
.
Change to load frequency
2
.
Adjust according to
『
OUTPUT LIMITATION
』
3
.
Stop welding
Unable to
activate
the Idle control
feature
1
.
Idol control switch is to
『
ECO
』
or
『
AUTO
』
2
.
Idol control switch is to
『
HIGH
』
3
.
The power consumption of
the load is 1A or below
4
.
Welding output short circuit
1
.
Turn to
『
HIGH
』
2
.
Turn to
『
ECO
』
or
『
AUTO
』
3
.
Set the idol control to
『
HIGH
』
4
.
Resolving short circuit
Unable to adjust
the welding
current by
remote controller
1
.
Connected AC load to
remote control receptacle
2
.
The switch(breaker) on the
cord reel at OFF
1
.
Disconnect AC load
2
.
Turn to ON
No welding and
AC output with
indicated “Err”
on the display
1
.
Left the welding output short
circuit
1
.
Stop the engine and
resolving short circuit
Summary of Contents for DGW300M