- 19 -
①
Turn the idle control switch and frequency change switch, according to the
operation.
②
Turn the display selector switch to
『
DC CURRENT
』.
③
Set the amperage by the current adjustment dial.
The preset current is indicated on the display with “PRESET” indicator lamp
turned on.
Whenever welding operation start, the actual current is indicated on the
display with “ACTUAL” indicator lamp turned on.
9-1
.
.
.
.
Output Range
1-Phase 200V/220V Output is available through 2 receptacle sets.
Maximum output by 1 receptacle is 2.2kVA/2.4kVA.
Maximum output by 2 receptacle sets is 4.4kVA/4.8kVA.
9-2
.
.
.
.
Output Limitation
Please refer to the following table, because electric tools and home appliances
cannot be judged only by the rated output or the power consumption due to the
efficiency and character of the components.
Applicable Load (For reference purpose only)
Capacity (Unit
:
kW)
Loads
Receptacle
1 set
Receptacle
2 sets use
Electric Bulb, Heater, etc.
2.2(50Hz)
2.4(60Hz)
4.4(50Hz)
4.8(60Hz)
Electric Tools(Series Motor),
etc
1.1(50Hz)
1.2(60Hz)
2.2(50Hz)
2.4(60Hz)
Mercury Bulb
(High Power Factor Type)
0.8(50Hz)
0.9(60Hz)
1.7(50Hz)
1.9(60Hz)
Submersible Pump,
Compressor, etc
(Induction Motor)
0.8(50Hz)
0.9(60Hz)
1.7(50Hz)
1.9(60Hz)
※
Series Motor : Motor with brush
※
Induction Motor : Brushless Motor
※
The value described is
『
OUTPUT
』
for Induction Motor loads and
『
POWER CONSUMPTION
』
for the other equipment.
< Caution >
•
Be sure to confirm the frequency designated in the equipment incorporated in
mercury bulb or induction motor.
9
.
.
.
.
Generator Operation
CURRENT
ADJUSTMENT DIAL
DISPLAY
IDLE CONTROL
SWITCH
DISPLAY
SELECTOR SWITCH
ACTUAL LAMP
PRESET LAMP