15
Circuit Breaker
Power Switch
Voltage
Regulator
Earth Leakage
Relay
Hour Meter
(6) Water in Fuel
If the liquid stored in the water separator exceeds approximately 110 ml during operation,
"Water in Fuel" appear on the Operation Display. If it illuminates, immediately stop the
engine and drain the liquid stored in the water separator.
(Refer to section “
10.
Inspection/Maintenance (4) Draining Liquid in Water Separator
”.)
(7) Charge Alt Failure
"Charge Alt Failure" appear on the Operation Display when charging is not possible
during operation.If charging is not possible and the battery voltage drops below 8 V, the
ENGINE warning indicator also lights up and the engine automatically stops. If this
occurs, contact the authorized distributor where the generator was purchased.
(8) Fuel Level Low
If the amount of fuel is small, "Fuel Level Low" appear on the Operation Display, and the
engine will be automatically stopped. Check if there is a sufficient amount of fuel and
add fuel insufficient.
5-3. Meters and Switches
Meters
(1) Hour Meter
Displays the operating time. Use this as a reference for managing periodic inspection
interval.
< Note >
EngineRunTime of controller and HourMeter value may not be matched. In that case,
you check the HourMeter time.
Switches
(1) Power Switch
This is the main Power Switch of the generator.
When the Power Switch turned to OFF position, the engine is stopped.
< Note >
If there is no operation for about 6 minutes while the engine is stopped, it will shift
sleep mode to reduce battery consumption. Once it shift to sleep mode, the display of
the Operation Display will disappear. To exit sleep mode, press any button on the
controller.
If the engine is not started for a long time when the Power Switch is ON position, the
battery will deteriorate.