38
Accumulation of carbon (soot, unburned fuel) in the exhaust system could cause engine
output loss and/or engine fault. To eliminate soot and unburned fuel, run the unit at
more than 70% of the rated output for about half an hour, until the exhaust gas become
mostly colorless. The carbon will accumulate when the unit runs at less than 30% of
rated output.
< Note >
When the unit operates at rated power, accumulation of carbon in the exhaust pipe line and
muffler might be lead to back fire incident. Do not bring flammable items that are highly
combustible near the generator.
CAUTION : FIRE
Always be sure to wipe up any spilled fuel or oil.
Allow the generator to cool before covering with the protective cover.
CAUTION : BURNS
Do not touch the engine and surrounding components immediately after
stopping the engine as they are still extremely hot.
(1) Storage Procedures
Perform the following maintenance procedures before storing this generator if it is not
going to be used for two months or more.
Remove the battery.
(
Refer to section “
8-7. Checking the Battery Replacing the Battery
”.)
Replace the engine oil.
(
Refer to section “
10. Inspection/Maintenance (1) Engine Oil Replacement
”.)
Drain the fuel from the fuel tank and filter.
(
Refer to section “
10. Inspection/Maintenance (5)
Fuel Filter
Cleaning/Replacement
”.)
(
Refer to section “
10. Inspection/Maintenance (6) Draining Water from the Fuel
Tank
”.)
Turn the Power Switch to OFF position and store in a secure location.
Clean up all generator components, and store in a dry and dust-free location. Also cover
when storing so that rain cannot enter through the suction or exhaust ports.
< Note >
Adjust the fluid of the removed battery to the appropriate level and recharge approximately
every month.
Clean
Every 200 hours
WARNING : INJURY
Before performing any equipment check or maintenance, stop the engine, and
turn the Power Switch to OFF position.