Operating procedure
Display panel
(1)
Push after inputting the
program.
(2) Input time.
For example 65min.
(3)
Push
The indicator
lights off.
Operating procedure
Display panel
(1)
Push after inputting the
program.
(2)
Push
(3)
Input the starting time of firing.
For example 13:34
(4)
Push
(5)
Push
The indicator
lights off.
Operating procedure
(1)
Push and input another program.
18
1 Timer
※
If you do not operate any keys for
10 seconds, the display turns back
to show the kiln temperature.
You can set the timer in the following 2 ways.
Time shows 24 hours a day.
Range to input
Within 23 hours and 49
minutes
Unit of time is “minute”
Maximum 9999 minutes
(6.9 days)
Minimum 0 minutes
2. What time you start firing.
1. In how many minutes you start firing after pushing key.
1.In how many minutes you start firing after pushing key.
2.What time you start firing
→
Self
Prog.
Basic
Prog.
Convenient functions of controller
1 Timer
6
shows flashing.
shows flashing.
When you want to cancel the timer you set
Setup of Timer
P.12