RANGE HOOD INSTALLATION INSTRUCTIONS 

FOR ADA COMPLIANCE

For questions about features, operation/performance, parts, accessories, or service, call: 

1-800-253-1301

.

In Canada, for assistance, installation, and service, call: 

1-800-607-6777

.

Residential range hoods can be installed to comply with Sections 308 and 309 of ADA Guidelines when used with appropriately 

mounted controls installed at 15" (38.1 cm) to 40" (101.6 cm) above the floor, and control access should not require reaching over  

a cooking appliance.
The following range hoods can work in an ADA-compliant situation when the range hood is wired to operate from a dedicated 

standard electrical wall switch. To facilitate this application, share the information on the following pages with your electrician  

when preparing for the installation.

NOTE:

 All the models can be controlled only by one remote switch. The switch activates or deactivates the motor and the light 

of the hood.

INSTALLATION REQUIREMENTS

Tools and Parts

Tools Needed

Wire stripper

#2 Phillips 

screwdriver

Flat-blade 

screwdriver

Parts Needed

UL Listed/CSA 

Approved wire 

connectors

UL Listed/CSA 

Approved  

1/2" (13 mm)  

strain relief

UL Listed #14 

(minimum)  

3 wire cable

UL Listed single pole 

toggle light switch

UL Listed deep  

single-gang  

switch box

Electrical Requirements

Observe all governing codes and ordinances.
Ensure that the electrical installation is adequate and in 

conformance with National Electrical Code, ANSI/NFPA 70 

(latest edition), or CSA Standards C22.1-94, Canadian Electrical 

Code, Part 1 and C22.2 No. 0-M91 (latest edition) and all local 

codes and ordinances.
If codes permit and a separate ground wire is used, it is 

recommended that a qualified electrician determine that the 

ground path is adequate.
A copy of the above code standards can be obtained from:

National Fire Protection Association 

1 Batterymarch Park 

Quincy, MA 02169-7471

CSA International 

8501 East Pleasant Valley Road 

Cleveland, OH 44131-5575

 

A 120-volt, 60 Hz., AC-only, 15-amp fused electrical circuit  

is required.

Two-Speed Range Hoods 

(with rocker switch)

Intermediate Range Hoods 

(with rotary switch)

Three-Speed Range Hoods 

(with push buttons)

 

UXT20

 

UXT30

 

UXT40

 

UXT41

 

UXT42

 

UXT52

 

WVU37U

W11108368A

Summary of Contents for UXT20

Page 1: ...pper 2 Phillips screwdriver Flat blade screwdriver Parts Needed UL Listed CSA Approved wire connectors UL Listed CSA Approved 1 2 13 mm strain relief UL Listed 14 minimum 3 wire cable UL Listed single pole toggle light switch UL Listed deep single gang switch box Electrical Requirements Observe all governing codes and ordinances Ensure that the electrical installation is adequate and in conformanc...

Page 2: ...tach the power cable to the switch box Clamp wiring to switch box and unit using a UL Listed or CSA Approved 1 2 13 mm strain relief Provide 6 15 2 cm leads inside box and fan for easier wiring 3 Connect wiring General instructions for all models Make sure both the single pole toggle light switch and the range hood are properly grounded Make sure the ground wire is securely fastened to the single ...

Page 3: ...Tournevis à tête cruciforme nº 2 Tournevis à lame plate Pièces nécessaires Capuchons de connexion homologués UL CSA Serre câble de 1 2 13 mm homologué UL CSA Câble 3 fils nº 14 minimum homologué UL Interrupteur d éclairage à bascule unipolaire homologué UL Boîte d interrupteur profonde à commande unique homologué UL Spécifications électriques Observer les dispositions de tous les codes et règlemen...

Page 4: ...eur Serrer le câblage à la boîte d interrupteur et à l unité au moyen d un serre câble de 1 2 13 mm homologué UL CSA Prévoir des fils de 6 15 2 cm à l intérieur de la boîte et du ventilateur pour faciliter le câblage 3 Raccorder le câblage Instructions générales pour tous les modèles S assurer que l interrupteur d éclairage à bascule unipolaire et la hotte de cuisine sont correctement mis à la ter...

Reviews: