37
Magnetically Levitated Turbo Molecular Pump
INSTRUCTION MANUAL
7
OPTION
A gas purge adaptor with an orifice is available as an option. The gas purge adaptor with an
orifice maintains the purge gas flow between 20 and 30 mL/min if the gas-supply pressure lies
within the range below. Flow control with a flowmeter is not required.
Note: Gas purge adaptors with no orifice are recommended for applications in which large
amounts of reaction products are generated (e.g., metal etchers). Adaptors with an orifice
willcause clogging.
Fig. 7-3
Gas Purge Method (
diameter of orifice is
φ
0.05mm
)
Table. 7-2
Table of Gas-purge Ports (
diameter of orifice is
φ
0.05mm
)
Gas supply
20
±
10 kPa gauge pressure (nitrogen gas)
Gas feed start
After starting backing vacuum pump; before evacuating process gas
Gas feed stop
After fully exhausting process gas; before stopping backing vacuum pump
Type of gas
Nitrogen gas or argon gas (Purity > 99.99%)
Joint
PART No.
Description
KF10
262-77592-03
GP ADAPTOR, 802 KF10
UJR 6.35
262-77592-01
GP ADAPTOR, 802 UJR
SWAGELOK
φ
6.35
262-77592-06
GPA, SS-400 STRAIGHT
4-VCR
262-77592-14
GP ADAPTOR, 4-VCR
PURGE PORT
FLOW ALARM
VACUUM CHAMBER
TURBO MOLECULAR
PUMP
BACKING VACUUM PUMP
FILTER
VALVE
REGULATOR
GAS
SOURCE
FLOWMETER WITH
Summary of Contents for TMP-3203LM
Page 13: ...Table of contents xii 263 13236 This page is intentionally left blank...
Page 20: ...2 2IDENTIFICATION AND FUNCTION 2 1 Pump Main Unit...
Page 22: ...3 3CONSTRUCTION AND PRINCIPLE 3 1 Pump Construction 3 2 Principle of Turbo Molecular Pumping...
Page 41: ...SECTION 5 INSTALLATION 28 263 13236 5 This page is intentionally left blank...
Page 48: ...7 7GAS PURGE...
Page 51: ...SECTION 7 GAS PURGE 38 263 13236 7 This page is intentionally left blank...
Page 56: ...9 9TROUBLESHOOTING 9 1 Vacuum Pressure Rise 9 2 Abnormal Noise and or Vibration...