FOCUS HT Dental Porcelain Furnace Page 7
Manual version 4.3
2.3
Control Keys:
The 4 control keys are:
ON/OF
F
Turns the furnace on/off.
Switching to Idle mode.
STOP/
LIFT
Raising and lowering the platform.
Interrupting a firing cycle.
START
Starting a firing cycle.
HOLD
Temporarily “freezes” the firing cycle.
2.4
Programming keys:
PROG -
(PROGR
AM)
Sets the furnace into the mode for program selection.
ARROWS
keys
Closing and opening the table and toggle between the
different parameters in the editing mode
2.5
Displays:
The “program status” display shows the Status of the selected program.
(Cycle /Stop/ hold) located in left upper corner.
The “program Time” screen displays either the selected program remaining
time or 00:00 while not in cycle located in middle upper section.
The “temperature and data” display screen displays the temperature during the
Cycle, the symbol
C is displayed together with the temperature when degrees
in Celsius are defined, and the symbol °F when the degrees are in Fahrenheit.
Located in right upper section.
“Vacuum” display is used when keying in the vacuum parameters of the cycle.
During the cycle, the “vacuum” screen displays the actual vacuum level, located
in the lower left corner.
On the right lower side appear the running parameter in real time.