FOCUS HT Dental Porcelain Furnace Page 18
Manual version 4.3
5.6
Manual Pre-Heating/Drying
User can manually raise the platforms to any height in order to heat up an object or in
case additional pre-heating is required. In order to perform it, you should choose the
program number
(PROG# - ENT),
with
START TEMP
you will need to receive the optimal
preheating.
1.
Press the UP arrow continuously and the platform will start
to rise. Move the platform by pressing the UP arrow until
the required distance between the object and the opening of
the muffle is achieved.
2.
In order to lower the platform - use the DOWN arrow
continuously. Using the “Final temp” feature.
5.7
Using the “Final temp” feature
To activate the Final temp feature, you need to go to Option screen. First, go to the OPTION
screen and chose the 11-parameter field- while the 11 is highlighted press ENT again. It
will automatically change to 13-parameter.
Now when editing the program When the FINAL TEMP parameter will be lower than HIGH
TEMP, then FINAL TEMP and FINAL DELAY parameters can act like TEMPERN effect i.e.
temperature will drop down to FINAL TEMP and will remain at that temperature for the
defined FINAL DELAY period.
This feature is optimal for ceramic over metal or zirconia that require slow cooling.
POINTS TO NOTE
When programming data into a parameter, check that the data is correct and that it
correlates with the other parameters.
Remember that parameters have limits, if you enter data above or below these limits
the data will not be entered.
In the event of an error, the warning tone will sound by pressing START and the
firing cycle will not start. The erroneous parameter will blink indicating the source of
the problem. This parameter isn’t logical or it is out of the permitted limits.