-69
Maintenance Indicators
■
The warning lights on the projector indicate problems inside the projector.
■
If a problem occurs, either the temperature warning indicator or the lamp indicator will illuminate
red, and the projector will enter the standby mode. After the projector has entered the standby
mode, follow the procedures given below.
About the temperature warning indicator
If the temperature inside the projector increases, due to blockage of the air vents, or the setting location,
“
” will illuminate in the lower left corner of the picture. If the temperature keeps on rising, the lamp will
turn off and the temperature warning indicator will blink, the cooling fan will run for a further 90 seconds, and
then the projector will enter the standby mode. After “
” appears, ensure you perform the measures
described on page
70
.
About the lamp indicator
“Change The Lamp. (LAMP 2)” is displayed when the remain-
ing life of the lamp 2 becomes 5% or less.
■
When the remaining lamp life becomes 5% or less, “
” (yellow) and “Change The Lamp. (LAMP 1/
2)” will be displayed on the screen.
■
When the percentage becomes 0%, it will change to “
” (red), the lamp will automatically turn off. At
this time, the lamp indicator will illuminate
in red.
If you try to turn on the projector a fourth time without replacing the lamp, the lamp whose life is 0%
will not light up.
Power indicator
Lamp (1, 2) indicators
Temperature warning indicator
Maintenance Indicators
Indicators on the Projector
Red on
Green on
Red blinks
Green blinks
Green on
Green blinks
Red on
Off
Red on
Power indicator
Lamp (1, 2)
indicators
Temperature
warning indicator
Normal (Standby)
Normal (Power on)
Abnormal (See page
70
.)
Normal (Cooling)
Normal
The lamp is warming up.
The lamp is shut down abnormally or requires to be changed. (See page
70
.)
Normal
The internal temperature is abnormally high. (See page
70
.)
Summary of Contents for XG-P560W - WXGA DLP Projector