#7. Chips Welded To Tooth Tips
Probable Cause :
A.
Insufficient sawing fluid due to inadequate supply,
improper ratio and/or improper application.
B.
Worn, missing or improperly positioned chip brush.
C.
Improper band speed.
D.
Improper feeding rate.
#8. Gullets Loading Up With Material
Probable Cause :
A.
Too fine of a tooth pitch – insufficient gullet capacity.
B.
Excessive feeding rate producing too large of a chip.
C.
Worn, missing or improperly positioned chip brush.
D.
Insufficient sawing fluid due to inadequate supply,
improper ratio and/or improper application.
#9. Discolored Tips Of Teeth Due To Excessive Frictional Heat
Probable Cause :
A.
Insufficient sawing fluid due to inadequate supply,
improper ratio and/or improper application.
B.
Excessive band speed.
C.
Improper feeding rate.
D.
Band installed backwards.