MINOR TROUBLES & SOLUTIONS
TROUBLE
PROBABLE CAUSE
SUGGESTED REMEDY
Saw blade motor does not run
even though blade drive button
is pressed.
Overload relay activated
Reset
Saw blade is not at forward
limit position.
Press SAW FRAME
FORWARD button
MOTOR TROUBLES & SOLUTIONS
TROUBLE
PROBABLE CAUSE
SUGGESTED REMEDY
Motor will not start
Magnetic switch open, or
protector open.
Reset protector by pushing red button (inside
electric box.)
Low voltage
Check power line for proper voltage.
Open circuit in motor or loose
connections.
Inspect all lead terminations on motor for loose
or open connections.
Motor will not start,
fuse or circuit
breakers “blow”.
Short circuit in line, cord or
plug.
Inspect line, cord and plug for damaged
insulation and shorted wire.
Short circuit in motor or loose
connections
Inspect all lead terminations on motor for loose
or shorted terminals or worn insulation on
wires.
Incorrect fuses or circuit
breakers in power line.
Install correct fuses or circuit breakers.
Motor fail to develop
full power. (Power
output of motor
decreases rapidly
with decrease in
voltage at motor
terminals.)
Power line overloaded with
lights, appliances and other
motors.
Reduce the load on the power line.
Undersize wires or circuit too
long.
Increase wire sizes, or reduce length of wiring
General overloading of power
company‘s facilities.
Request a voltage check from the power
company
Motor overheat
Motor overloaded.
Reduce load on motor
Air circulation through the
motor restricted.
Clean out motor to provide normal air
circulation through motor.
Motor stalls
(Resulting in blown
fuses or tripped
circuit breakers)
Short circuit in motor or loose
connections.
Inspect terminals in motor for loose or shorted
terminals or worn insulation on lead wires.
Low voltage
Correct the low line voltage conditions.
Incorrect fuses or circuit
breakers in power line.
Install correct fuses circuit breakers.
Summary of Contents for SW-100H
Page 1: ...SW 100T Instruction Manual Version 1 20171114 ...
Page 2: ......
Page 12: ...Illustration Emergency Stop Emergency Stop Button ...
Page 14: ...Illustration Safety Labels SW 100T SafetyLabels ...
Page 19: ...FLOOR PLAN Machine top view Machine front view ...
Page 20: ...Machine front view ...
Page 47: ...Section 5 ELECTRICAL SYSTEM ELECTRICAL CIRCUIT DIAGRAMS ...
Page 48: ......
Page 49: ...Section 6 HYDRAULIC SYSTEM HYDRAULIC CIRCUIT DIAGRAM ...
Page 50: ......
Page 74: ......
Page 75: ......
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ......
Page 82: ......
Page 83: ......