37
E
Controlling the Monitor with a computer (RS-232C)
You can control this monitor from a computer via RS-232C
(COM port) on the computer.
Computer connection
Connect with RS-232 straight cable between the computer’s
COM port (RS-232C connector) and the RS-232C input
terminal on the monitor. The terminal on the monitor is a
female-type connector.
RS-232 straight cable
(commercially available)
To COM port
Computer
RS-232C
input terminal
Communication conditions
Set the RS-232C communication settings on the computer to
match the monitor’s communication settings as follows:
Baud rate
9600bps
Stop bit
1 bit
Data length
8 bits
Flow control
None
Parity bit
None
Communication procedure
n
Command format
When a command is sent from the computer to the monitor,
the monitor operates according to the received command and
sends a response message to the computer.
C1
C2
C3
C4
P1
P2
P3
P4
Return code
Command field
(4 prescribed
alphanumerical characters)
Parameter field
(4 character string comprised of:
0-9, space, ?)
Example: VOLM0030
* Be sure to input 4 characters for the parameter.
(“ ” is a return code (0D
H
, 0A
H
or 0D
H
))
Wrong : VOLM30
If a command has “R” listed for “Direction” in the
“RS-232C command table” on page 39, the current value can
be returned by using “?” as the parameter.
Example:
VOLM ? ? ? ?
←
From computer to monitor (How
much is current volume setting?).
30
←
From monitor to computer
(Current volume setting: 30).
TIPS
• Send Command field, Parameter field and Return code
at the same time. When sending a command manually in
1 character units and it takes more than 2 seconds, the
command function does not work.